Message Meaning – Action Required
Relay n Cannot be
Heard by the Base
Notify Supervisor
The terminal has established contact with Relay
Station x. Relay Station x has attempted to
communicate with the Base Station through the 422
cabling with no success. Cable is bad.
Transmission Failed
To Retry, Move Closer
And Press Enter
The terminal has tried 10 times to get its message
through to the Base Station with no success. Could
be result of bad radio in base or terminal. Could be
the operator has gone out of range of the base- if so,
move closer and press any key. Could also be that
there are too many terminals competing for radio
time on one base station.
Two Way Not Allowed
Base in Other Mode
Press <Enter> Key
Sign On is not allowed if the Base is already in some
other mode such as One-Way or Site-Testing, which
was not properly concluded. Cycling power on base
clears. Is another Base giving you this message?
One Way Not Allowed
Base in Other Mode
Press <Enter> Key
One-Way is not allowed if the Base is already in
some other mode such as Two-Way or Site Testing
which was not properly concluded. Cycling power on
base clears.
Site Testing Not
Allowed, Base in
Other Mode
Press <Enter> Key
Site Testing is not allowed if the Base is already in
some other mode such as Two-Way or One-Way
which was not properly concluded. Cycling power on
base clears.
Base is not Jumpered
for Programming
Cannot Setup
Press <Enter> Key
The Base must have JP103 set to P before it can be
Setup through the Terminal. If Jumper is set
correctly, there must be another base answering.
Turn off the suspect base and try signing in again. If
you get the same message, another base is on.
Base is Jumpered
For Programming
Cannot Proceed
Press <Enter> Key
The Base jumper (JP103) is set to P for
programming. Base jumper JP103 must be set to N
for normal usage, (non-programming). If jumper is
correctly set, there must be another base answering.
Turn off suspect base and try again.
No Firmware Detected
1 – Download Firmware
0 – Power off Terminal
Press 0 or 1 now_
The firmware has somehow been wiped out –
probably from an interrupted firmware download.
Press 1 to Download Firmware or press 0 to power
off the terminal.
Two or more terminals with the same ID can generate all kinds of strange
messages including those shaded above.
Two bases on the same frequency are big trouble.
Sometimes you get an error message and after checking, everything on the Base
seems to be set OK. Drop power on the suspect Base and try signing in again. If
you get the same message, there is another Base answering which should not be
on the same frequency.