User's Manual

Table Of Contents
A-2
Jumper Changes
Refer to the circuit board diagram on page A-1 for reference.
JP103 controls the Programming Mode for the Base or Relay. For
normal operation, leave this jumper in the Normal setting. To
program the Relay ID or to program the Base Stations Computer Port
settings from an R/F Terminal, move this jumper to P for
Programming Mode.
If the Base Station is jumpered for Programming, the user will be unable to
"SIGN ON" for communication and will see the following message
displayed:
BASE IS JUMPERED
FOR PROGRAMMING,
CANNOT SIGN ON
HIT ANY KEY
If the Base Station is set for Normal, the user will be unable to setup the
Base and will see the following message displayed:
BASE IS NOT JUMPERED
FOR PROGRAMMING,
CANNOT SETUP
HIT ANY KEY
After changing the N/P jumper (JP103), you must cycle power on the Base
Station or Relay for the new setting to take effect. After cycling power, you
can enter SETUP MODE on the R/F Terminal and make changes to the
Base Setup from the R/F Terminal.
All changes to the Base Station must be made from the RF Terminal keypad
only. This is to minimize confusion between setup of the R/F Terminal and
the R/F Base Station.
Refer to Base Setup instructions in Chapter 2; RF System Setup for
instructions on how to make the baud rate, parity, protocol, etc. changes to
the Base Station.