Appendix L
Piggyback Laser Installation
The RF Terminal can use a hand-held Laser scanner (such as the LZ100,
LZ200 and Symbol 3200 models) in what we call a "Piggyback"
configuration. This configuration has the RF Terminal connected to the
laser with a short cable and velcro strips to secure the RF Terminal to the
top of the laser. This creates an all-in-one RF Terminal/Laser scanner.
Follow these steps to complete the Piggyback installation:
1. If the normal long coiled laser cable is still plugged into the
LZx00 laser, use a pencil or flat head screwdriver to depress the
tab on the RJ45 connector of the cable at the base of the laser
scanner. Pull out the cable while depressing the tab.
2. Insert the untagged end of the T24 Piggyback cable into the laser.
This cable is considerably shorter than the original laser cable.
3. Place the velcro strips on the top of the laser and the back of the
RF Terminal separately according to the diagram below. Firmly
press on the velcro surface to be sure the sticky back makes
complete contact with the surface of the laser and RF Terminal.
4. Plug the tagged end of the T24 Piggyback cable into the RF
Terminal SCANNER port.
A carrying case, the T47 is available for this configuration. It is a one piece
carrying case designed to help stabilize and protect the RF Terminal and