SDS

_____________________________________________________________________________________________
1203658 - Positec 20V 1.5Ah Li batt.
Revision Date 02-Feb-2015
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 1
mg/m
3
Cu dust and mist
TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
dust, fume, mist
IDLH: 100 mg/m
3
dust, fume and
mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
Lithium nickel oxide (LiNiO2)
12031-65-1
TWA: 0.2 mg/m
3
Ni inhalable
fraction
TWA: 1 mg/m
3
Ni
(vacated) TWA: 1 mg/m
3
Ni
IDLH: 10 mg/m
3
Ni
TWA: 0.015 mg/m
3
except Nickel
carbonyl Ni
Nickel
7440-02-0
TWA: 1.5 mg/m
3
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 10 mg/m
3
TWA: 0.015 mg/m
3
Aluminum
7429-90-5
TWA: 1 mg/m
3
respirable fraction TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction (vacated)
TWA: 5 mg/m
3
Al Aluminum
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
Lithium manganese oxide (LiMn2O4)
12057-17-9
TWA: 0.2 mg/m
3
Mn (vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
Mn
IDLH: 500 mg/m
3
Mn
TWA: 1 mg/m
3
Mn
STEL: 3 mg/m
3
Mn
Manganese
7439-96-5
TWA: 0.02 mg/m
3
respirable
fraction
TWA: 0.1 mg/m
3
inhalable
fraction TWA: 0.02 mg/m
3
Mn
TWA: 0.1 mg/m
3
Mn
(vacated) TWA: 1 mg/m
3
fume
(vacated) STEL: 3 mg/m
3
fume
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
fume Ceiling: 5
mg/m
3
Mn
IDLH: 500 mg/m
3
TWA: 1 mg/m
3
fume
STEL: 3 mg/m
3
Lithium Cobalt Oxide (CoLiO2)
12190-79-3
TWA: 0.02 mg/m
3
-
Supplier Trade Secret TWA: 1 mg/m
3
respirable fraction -
Phosphate(1-), hexafluoro-, lithium
21324-40-3
TWA: 2.5 mg/m
3
F TWA: 2.5 mg/m
3
F
TWA: 2.5 mg/m
3
dust
(vacated) TWA: 2.5 mg/m
3
Carbon black
1333-86-4
TWA: 3 mg/m
3
inhalable fraction TWA: 3.5 mg/m
3
(vacated) TWA: 3.5 mg/m
3
IDLH: 1750 mg/m
3
TWA: 3.5 mg/m
3
TWA: 0.1 mg/m
3
Carbon black in
presence of Polycyclic aromatic
hydrocarbons PAH
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits Immediately Dangerous to Life or Health
7. HANDLING AND STORAGE
_____________________________________________________________________________________________
Precautions for safe handling
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Use personal protection equipment.
Conditions for safe storage, including any incompatibilities
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place.
Page 5 / 13
Incompatible Products
Strong acids. Strong oxidizing agents. Strong bases.