Blood Pressure Monitor Model No.GSH822 INSTRUCTION MANUAL PLEASE READ THIS INSTRUCTION MANUAL COMPLETELY BEFORE OPERATING THIS UNIT.
Content Important Information Before Use 1 Intended Use 2 Product Identification 2 Description of LCD Display 3 Battery Installation 4 Placement of the Cuff 5 Setting the Date and Time 7 Measurement of Pulse Rate and Blood Pressure 8 World Health Organization (WHO) 10 Irregular Heartbeat Detector 10 Bluetooth Function 11 Memory Function 12 Care and Maintenance 13 Troubleshooting 14 Error Codes 15 Technical Specification 16 Warranty Card 17 Explanation of Symbols 18
Content EMC Tables 19
Important Information Before Use To ensure user's safety and also the accuracy of the measurement, please read through the following information and follow the rules. 1. Do Not disassemble or reassemble this product yourself. 2. Do Not expose this product to high temperature, humidity or direct sunlight. 3. Please avoid extreme shaking or dropping the product from a high place, these actions will cause damage to the product itself. 4.
Intended Use GSH822 Blood Pressure Monitor applies the Oscillometric method to measure human systolic / diastolic blood pressure and heart rate.All values are shown on the LCD monitor. This device is designed only for adults. The measurement result will be transmitted to your mobile device through Bluetooth transmission.
Description of LCD Display Unit of Measurement Symbol Systolic Pressure Unit of Measurement Symbol Diastolic Pressure Irregular Heart Beat Symbol Unit of Measurement Symbol Inflation/Deflation Symbol Pulse Rate Alarm Clock Date Heartbeat Symbol Time Memory Symbol Average Measurement Symbol Low Battery Symbol Memory Sets WHO Indicator 3
Battery Installation Low battery warning: It is necessary to replace the batteries when the Low Battery symbol “ ” appears on the display, or when the display does not turn on after the POWER button is pressed. Replacing the Battery: 1. Press down on latch and lift the cover on the bottom of the monitor. 2. Insert or replace 4 x 1.5 V AA batteries into the battery compartment, ensuring to match the indicated polarity symbols. Always use new batteries. 3. Replace the battery cover. NOTE: Battery-operated 1.
Placement of the Cuff It is important to avoid smoking, eating, taking medication, alcohol consumption or physical activity 30 minutes prior to taking a reading. If for any reason you are unable to or should not use your left arm, please modify the instructions for cuff application to your right arm. Your physician can help you identify which arm is best for you to take measurements from. (1) Remove any constrictive clothing or jewelry that may interfere with cuff placement.
Placement of the Cuff (8) Reaching underneath your left arm with your right hand, pull the end of the cuff towards your body to tighten the cuff. Wrap and secure the cuff, making sure that the ( ) mark remains in place as shown. (9) The cuff should fit comfortably, yet snugly around your arm. You should be able to insert one finger easily between your arm and the cuff. (10) The cuff size is suitable for use when the vertical ‘index’ mark is within the horizontal OK range.
Setting the Date and Time It is necessary to set the date and time for the unit every time batteries are initially installed or replaced. (1) While in power off mode, press the Date and Time Set button to enter Date and Time setting procedure and the Year value will begin to flash. (2) Press the MEMORY button to advanced the display to the desired year, then press the Power button to confirm the year. (3) Next, the month will blink. Repeat step 2 to finish the setting procedure.
Measurement of Pulse Rate and Blood Pressure Please read the preceding portions of this manual prior to taking your first reading. (1) Position the monitor on a flat, stable surface with the digital display in view. (2) Insert the cuff tubing connector into the port on the left side of your monitor. (3) Rest your elbow on a solid surface with your palm facing upward. Elevate your arm so that the cuff is at the same level as your heart. Relax your left hand. (4) Press the POWER button.
Measurement of Pulse Rate and Blood Pressure (9) To detect the heartbeat, the heartbeat symbol will appear and continuous flashes on the LCD display. (10) Your blood pressure measurement and pulse will display simultaneously on the screen. (11) The Hypertension Indicator will indicate your reading range on the display separately. (12) Your reading will be automatically stored in “MEMORY Recall” Button . (13) If you do not press any button, the device will automatically shut-off approximately 2 minutes.
World Health Organization (WHO) Diastolic Blood Pressure This unit features our unique Hypertension Indicator. The World Health Organization has established globally accepted standards for the assessment of high or low blood pressure readings. The below chart should be considered only as a guideline, always consult with your physician or health care professional to interpret your individual results.
Bluetooth Function (1) GSH822 with Bluetooth can transmit the measurement data to your mobile device. (2) Please make sure your mobile device has BLE 4.0 technology for connecting GSH822. (3) GSH822 can support iOS and Android operation system. (4) Please download and install Wow Go Health APP and then follow the instruction to complete registration. (5) Click “BP measurements” and then tap the Bluetooth icon for creating connection with GSH822.
Memory Function (1) In power off mode, press and release the MEMORY button. The device will show the average value of the latest three records. (2) Continue to press the MEMORY button to successively view the next previously stored measurements. Measurement data will appear on the display form most current to oldest; the memory number will appear on the lower left corner.
Care Care and and Maintenance Maintenance (1) Clean the device and arm cuff carefully only with a slightly moistened cloth. (2) Do not immerse the device in water. It may cause damage if water enters. (3) Do not use any gas, strong detergent, or solvents to clean the device, including the arm cuff. (4) Disconnect the cuff and tubing from the monitor prior to storing. (5) Do not use any liquids on the monitor or cuff. (6) Use a soft, dry cloth to clean your monitor.
Troubleshooting Problem Probable Cause Recommended Action Batteries are drained. Replace all batteries with new ones. Battery are not correct ly aligned with terminals. Reinsert batteries in the correct position. Batteries are drained. Replace all batteries with new ones. In colder temperatures batteries have weaker electrical charges. Warm up the batteries, or use the device in a warmer setting. Device operation time is inconsistent. Different battery brands have different life spans.
Error Codes Err Code Err 00 Err 01 Err 02 Err 03 Err Corrective Action Meaning No pulse or detect pulses not enough. Take off heavy clothes and retry again. Leakage in Cuff Pressure/Inflation too low. The wrist cuff is not fastened properly. Re- apply the cuff, and take a measurement again. Pressure fault. Rest a while, relax and retry again. Deflation fault. The wrist cuff is not fastened properly. Re- apply the cuff, and take a measurement again. Memory error.
Technical Specifications Power Source : 4 x 1.5 V AA alkaline batteries Dimensions : 143mm x 93mm x 56mm (LxWxH) Weight : approx. 390g (exclude batteries and storage base) Cuff Circumference (M size) : approx.
Warranty Card Note : (1) Normal users enjoy one year of free maintenance service from the date of purchase, please directly contact the distributor first. (2) Consumable materials are not covered by the warranty. (3) If the product is out of warranty, the maintenance cost will be charged. Non-warranty situation : (1) Damage caused by improper use. (2) Unauthorized modification and disassembly (3) The card is damaged or lost. (4) Damage caused by human factors such as shock or drop.
Explanation of Symbols The CE marking with the Registration Number of the Notified Body. This denotes the compliance of European Medical Device Directive 93/42/EEC Follow instructions for use Disposal information: Should you wish to dispose of the article, do so in accordance with current regulations.
EMC Tables Guidance and manfacturer’s declaration-electromagnetic emissions The GSH822 Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the GSH822 Blood Pressure Monitor should assure that it is used in such an environment.
EMC Tables Guidance and manfacturer’s declaration-electromagnetic immunity The GSH822 Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the GSH822 Blood Pressure Monitor should assure that it is used in such an environment. Immunity test IEC 60601 Compliance test level level Radiated RF 3 V/m IEC 61000-4-3 80 MHz to 2.
EMC Tables Recommended separation distances between portable and mobile RF communications equipment and the GSH822 Blood Pressure Monitor The GSH822 Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Distributed by : Golden Smart Home Technology Corp. Address : Rm. 206, No. 47, Yuanqu 2nd Rd., Hsinchu Science Park, Hsinchu City, Taiwan, R.O.C 30075 Web : www.goldensmarthome.com.