Instructions

46
EN
DANGER!
Risk of fatal electric shock when
touching electrical components.
Carry out all installation and connection work only
in an isolated, de-energised state.
Disconnect all phases of the mains power cable
and secure it to prevent any reconnection.
Check that the system is de-energised.
WARNING!
Risk of short-circuit resulting from water in the
event of improper cabling.
Never lay the motor cable (15) vertically upwards
otherwise water may collect on the cable and run
into the motor, leading to damage.
Lay the cable in a loop. The loop will cause any
water on the cable to collect at the lowest point,
from where it can drain off.
8. Safety information regarding the electrical connection
WARNING!
Risk of short-circuit resulting from damaged
cable.
Lay all cables in the roller shutter box so that they
cannot be damaged by moving machinery.
The mains connection for the drive may only be
connected with the same conduction type. Con-
sult customer services if necessary.
Fixed-installation devices...
...must be equipped on the installation side with a
circuit-breaker for each phase in accordance with
DIN VDE 0700. Switches with a contact opening
width of min. 3 mm can be used as circuit-breakers
(e.g. power switch, power circuit breaker or residual-
current-operated circuit-breaker).