Instructions

54
EN
13. Technical specifications
in order to ensure trouble-free operation of
RADEMACHER tubular motors with KNX/EIB
Venetian blind actuators, the following parameters
must be configured prior to commissioning:
Transient operation
If possible, transient operation (slat adjustment)
should be switched off.
e.g. Mode for transient operation
Time: = 0 ms
14. Configuration of KNX/EIB Venetian blind actuators for
RADEMACHER tubular motors
If transient operation cannot be deactivated
from within the software application...
...then you must ensure that the time between
transient operation and long-term operation on the
key sensor is less that the time between transient
operation and long-term operation on the actuator.
This will ensure that transient switch-off of the actua-
tor is prevented when holding the sensor key down.
Long-term operation
The motor must be switched off at the latest after
180 seconds.
e.g. Basis for long-term operation
Basis: = 2.1 s
Factor: = 86
= (2.1 s x 86 = 180.6 s)
Motor series: CLIS xx/xx PZ CLIM xx/xx PZ
Nominal torque: Nm 6 10 10 20 30 40 50
No-load speed rpm 28 16 16 16 16 16 12
Nominal voltage V 230 230 230 230 230 230 230
Frequency Hz 50 50 50 50 50 50 50
Nominal power W 121 121 112 145 191 198 205
Current consumption A 0.53 0.53 0.49 0.64 0.83 0.86 0.89
On-period (KB) min. 4 4 4 4 4 4 4
Number of wires 5 5 5 5 5 5 5
Core cross section mm
2
0.75 0.75 0.75 0.75 0.75 0.75 0.75
Plug-in connection cable (PVC) m 2.5 2.5 2.5 2.5 2.5 2.5 2.5
End switching range:
(number of revolutions.)
r 64 64 64 64 64 64 48
Insulation class H H H H H H H
Protection class I I I I I I I
Protection type in accordance with
VDE 700
IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Motor length without bearing mm 485 485 487 487 546 546 546
Tube diameter mm 35 35 45 45 45 45 45
Sound pressure level (LpA) dB(A) ≤ 70 ≤ 70 ≤ 70 ≤ 70 ≤ 70 ≤ 70 ≤ 70
Number of parallel tubular motors that
can be connected in parallel when using
RADEMACHER controllers,
e.g. Troll Comfort
3 3 2 2 2 2 2
i
i