User manual

EN
46
5.
3.
4
You can correct the end point in small steps by briefly pressing the set button (11).
Important
In the event that a malfunction occurs during configuration, e.g. in the event that the tubular motor only runs for a single rotation even when
the set button is pressed, it is unlikely that the tubular motor is faulty. Possibly the adapter (10) has slipped off of the motor head.
Check and, if necessary, correct the positioning of the adapter (10), see pages 37 and 51.
Press and hold the corresponding set button (11) until the upper end point is reached.
Release the set button (11) as soon as the roller shutters have reached the desired position.
The motor stops and the upper end point is stored.
Manually setting the upper end point and automatically setting the lower end point
In order to do so, the tubular motor must be fully installed.
Never dismantle the mechanical stopper from the final roller shutter lamella.
The roller shutter box must be opened and the set button (11) on the tubular motor
must be freely accessible.
Do not allow the shutters to knock against the mechanical stops and maintain a
safety gap of 2 - 3 cm.
Risk of crushing injuries to the hand when working with the roller
shutter box open.
Never reach into the area of the rotating union when the motor is running.
Manual adjustment of end points
Initial installation
For initial installation, the roller shutter engineer can carry out the end point configuration
with the help of the set button (11) on the motor or with a commercially available
cord switch device (22) or external switch.
Further information can be obtained from the cord switch device operating instructions.
IMPORTANT
Operating the equipment without a stopper (20) may cause the roller
shutters to run into the roller shutter box and be damaged.
The roller shutters must always be fitted with a stopper (20) or end-rail.
End points must be set in order to switch off the motor when they are reached for
both directions of travel (up /down).
6. Finally move the roller shutters down (by briefly actuating the SET button or the external switch).
As soon as the roller shutters are fully closed, the tubular motor switches off automatically. The position of the
roller shutters will be stored as the lower end point.
NOTE
In the event that the end point configuration fails, you must reset the tubular motor to the factory setting (see page 50), in order to repeat the process.
To conclude the process, disconnect the tubular motor from the power for a few seconds (e.g. by switching the cord circuit
setting unit (22) toggle switch back to the central position). Subsequently, the tubular motor is ready for operation.
IMPORTANT
If the external switch (h) lead is not used, then it must be connected to the neutral conductor (f) (see fig. k).
7.
2.
Symbols and actions when connecting a cord circuit setting unit (22)
or
when connecting an external switch.
1.
SET
First move the roller shutters upwards.
If the tubular motor is already logged on to the DuoFern network, then the direction of travel can also be specified with DuoFern transmitters.
This also applies to point 6.
IMPORTANT
First move the roller shutters upwards. If the roller shutters first move downwards, then the direction of travel must first be reversed by
pressing the SET button several times or by using the external switch.
The switching sequence for the SET button or the external switch is: OPEN/STOP/CLOSE/STOP, and so on.
ON
or
Switch on the mains power.
or
SET
or
or
OFF