Instructions

48
EN
5.
3.
or
4.
or
1.
SET
SET
or
SET
2.
6.
Automatically setting the upper end point and manually setting the lower end point
The roller shutters will travel to the upper stop until the tubular motor switches off automatically.
IMPORTANT
Never interrupt the sequence while the process is running. The roller shutters must be allowed to travel up without interruption.
Afterwards, the tubular motor will reverse and the roller shutters will move downwards.
Press and hold the corresponding set button* until the lower end point is reached.
* on the motor, the cord switch device (22) or the external switch.
Release the set button as soon as the roller shutters have reached the desired end point.
The motor stops and the lower end point is stored.
NOTE
These methods are useful if you want to leave the ventilation slats between the roller shutter lamella open.
You can correct the lower end point in small steps by briefly pressing the set button.
IMPORTANT
In the event that a malfunction occurs during configuration, e. g. in the event that the tubular motor only runs for a single rotation even when
the set button is pressed, it is unlikely that the tubular motor is faulty. Possibly the adapter (10) has slipped off of the motor head.
Check and, if necessary, correct the positioning of the adapter (10), see page 52.
NOTE
In the event that the end point configuration fails, you must reset the tubular motor to the factory setting (see page 50), in order to repeat
the process.
Finally, disconnect the tubular motor from the mains for a few seconds. Subsequently, the tubular motor is ready for operation.
IMPORTANT
The set lead (j) must be connected to neutral (f) after configuration of the end points.