2.
4. Release the SET button as soon as the roller shutters have reached the desired position.
The motor stops and the first end point is stored.
Press and hold the SET button or the external switch.
Additionally switch on the mains power.
After approx. 6 seconds the tubular motor starts and the roller shutters move up or down.
Switch off the mains power.
If a cord circuit setting unit (23) is being used, then the rocker switch must be positioned to the centre position.
1.
Manual setting of upper / lower endpoint with a cord circuit setting unit or
SET
SET
SET
with an external switch
3.
SET
+
You can correct the end point in small steps by briefly pressing the SET button.
IMPORTANT
In the event that a malfunction occurs during configuration, e.g. in the event that the tubular motor only runs for a single rotation even when
the SET button is pressed, it is unlikely that the tubular motor is faulty. Possibly the adapter (10) has slipped off of the motor head.
Check and, if necessary, correct the positioning of the adapter (10), see pages 41 and 56.
NOTE
The end points are maintained permanently even in the event of power failure.
5.
6. Switch off the mains power again.
Repeat points 2 to 5 for the second end point.
IMPORTANT
If the “external switch (h) lead is not used, then it must be connected to the neutral conductor (f) (see fig. n).
7.
OFFor
or
ON
or
+
or
or
OFFor
Symbols and actions when connecting a cord circuit setting unit (22)
or