Instructions

EN
58
Connecting / disconnecting DuoFern transmitters
2.
4.
Subsequently activate connect / disconnect mode on the desired DuoFern transmitter. In order to do so, please
refer to the operating manual for the corresponding DuoFern transmitter.
Activate connect / disconnect mode on the radio tubular motor by briefly pressing the set button (11).
The radio tubular motor is briefly running up and down and the motor set button (11) lights up orange by way
of acknowledgement.
3.
Switch on the mains power.
1.
ON
Symbols and actions when connecting a cord circuit setting unit (22)
or
when connecting an external switch.
or
Every DuoFern transmitter that is required for operation has to be assigned to the tubular
motor in order that the radio tubular motor can be controlled with a DuoFern transmitter.
You can assign a maximum of 20 DuoFern transmitters, e.g. DuoFern manual central
operating unit; DuoFern standard manual transmitter etc. to the radio tubular motor.
Connecting / disconnecting a DuoFern transmitter with the help of a set button
There are various ways to connect the DuoFern transmitter to the
radio tubular motor or to disconnect the radio tubular motor:
1. Connect / disconnect a DuoFern transmitter with the help of a set button on the
tubular motor.
2. Connect / disconnect a DuoFern transmitter with the help of the radio code.
3. Remotely log on / log off a DuoFern transmitter with the help of the DuoFern central
operating unit (please refer to the DuoFern central operating unit’s operating
manual).
5.
The radio tubular motor acknowledges successful connection / disconnection by starting up briefly and the set
button LED turns green.
NOTE
The status LED lights up red if the connect / disconnect process fails, for example if :
20 DuoFern transmitters have already been registered.
an unsuitable device (e.g. other DuoFern actuator) is registered.
an attempt is made to log-off a DuoFern transmitter that is not logged-on.
In addition, please observe the remaining time window in which you are able to connect or disconnect the DuoFern
transmitter to/from the radio tubular motor.
If necessary, you can subsequently connect / disconnect the next DuoFern transmitter. In order to do so, repeat
points 1 to 4.
6.
Set button (11) with LED
Points 1 to 4.