Troll Basic DuoFern 5615 / 5615-AL EN Instruction manual for the electrical connection and for commissioning Item No.: 3650 01 72 (ultra-white) 3650 01 82 (aluminium) VBD 600-2 (08.
i Dear Customer, EN With your purchase of a Troll Basic DuoFern, you have chosen a quality product manufactured by RADEMACHER. Thank you for the trust you have placed in us. The Troll Basic DuoFern has been designed both in order to provide optimal convenience and operability as well as to ensure solidity and durability. Having applied uncompromising quality standards and thorough testing, we are proud to be able to present this innovative product to you.
i Table of Contents i 1. 2. 3. 4. 5. Dear Customer,.....................................2 13. Set the motor running time.................26 13.1 Setting the motor running time Included in delivery ..............................4 with the Troll Basic DuoFern.............. 26 General view - operating unit................5 13.2 Time the running duration of 2.1 Brief description of the keys................5 The function of the keys and LEDs..........
i 1. Included in delivery 2. EN 3. 1. Legend 1. Control unit (50 x 50 mm) 2. Frame 3.
i 2. General view - operating unit EN Operating unit Sun LED Dawn LED Timer LED Timer key Dusk LED Up key Down key Sun key Dawn key Dusk key SET/Stop key i 2.1 Brief description of the keys The operating keys [ up / down ] ◆◆ Manual operation [ up / down ]. Sun key, [ ] ◆◆ Switches the automated solar function on/off. SET/Stop key, [ ] ◆◆ Manual stop or simultaneously switch all automatic functions on/off. Dawn key [ ] ◆◆ Switches the automatic dawn function on/off.
i 3. The function of the keys and LEDs Function EN Duration Key LED Action up / stop / down / stop Stop Automatic timer on / off 1s Lights red Automated solar function on / off 1s Lights red Automatic dawn function on / off 1s Lights red Automatic dusk function on / off 1s Lights red Automatic system on / off 1s max.
i 4. Key to symbols EN Risk of fatal electric shock. This sign warns of danger when working on electrical connections, components, etc. It requires that safety precautions be taken to protect the life and health of the person concerned. This concerns your safety. Please pay particular attention and carefully follow all instructions marked with this symbol. NOTE / IMPORTANT / CAUTION This is to draw your attention to information that is important for trouble-free operation.
i 5. Safety informations EN The use of defective equipment can lead to personal injury and damage to property (electric shocks, short circuiting). ◆◆ Never use defective or damaged equipment. Please contact our Customer Service department in the event of faults, see page 40. Incorrect use leads to an increased risk of injury. ◆◆ Train all personnel to use the Troll Basic DuoFern safely.
i 5.1 Intended use EN IMPORTANT Radio systems which transmit on the same frequency can cause interference. i 5.2 Improper use Using the Troll Basic DuoFern for purposes other than previously mentioned is impermissible and is regarded as improper use. Improper use can lead to serious injuries or property damage. ◆◆ Do not use the Troll Basic DuoFern for safety disconnection of the connected tubular motor. ◆◆ Never use the DuoFern radio system and its components (e.g.
i 6. Brief description EN The Troll Basic DuoFern serves as a DuoFern receiver for controlling roller shutters, Venetian blinds, slats or awnings by connecting a corresponding tubular motor. The Troll Basic DuoFern can be controlled individually on site or it can be integrated into a DuoFern network. Central control of DuoFern devices with a HomePilot® or DuoFern manual central operating unit.
i 6. Brief description EN Automatic functions All automated functions of the Troll Basic DuoFern are controlled via the DuoFern network. A complete overview of the functions can be found on page 12. Assembly The Troll Basic DuoFern can be integrated into most commercially available switch ranges with the help of a corresponding intermediate frame 50 x 50 (DIN 49075). Suitable switch ranges are detailed on the following page. i 6.1 Compatible switch ranges (www.rademacher.
i 6.2 DuoFern network function table EN DuoFern HomePilot® DuoFern environmental sensor DuoFern manual central operating unit 1 WR ConfigTool with DuoFern manual central operating unit RolloTron Comfort DuoFern DuoFern manual transmitter standard DuoFern wall controller DuoFern radio transmitter, flush-mounted DuoFern functions 1. Manual operation 2. Direct drive to a desired %-position * 3. Manual mode on / off 4. Automatic timer on / off 5. Random function 6. Automatic dawn function 7.
i 6.2 DuoFern network function table DuoFern functions 26. End point setting for RADEMACHER tubular motors via radio ** 27. Reset via radio (3-stage) 28. Single-button operation 29. Jog mode 30. Blinds mode 31. Standard slat position * / # 32. auto Tilt after manual stop direction "Down" * / # 33. auto Tilt in sunshine position * / # 34. auto Tilt in sunshine position * / # 35. auto Tilt after moving to a %-position * / # 36. Slat run time * / # 37.
i 6.
i 7. Important information prior to electrical installation and mounting EN Installation and electrical connection of the Troll Basic DuoFern may only be undertaken with the supplied installation housing [ 3 ]. The connecting terminals [ 4 ] are located at the bottom of the installation housing [ 3 ]. NOTE Installation housings for other variants of the Troll controller are not compatible.
i 7.1 Safety instructions for electrical connection EN Prior to connecting, check that the voltage / frequency on the type plate corresponds to the local mains conditions. There is a risk of fatal electric shock when touching electrical components. ◆◆ Carry out all installation and connection work only in an isolated, zero-volts state. ◆◆ Disconnect all phases of the mains power supply cable and secure it to prevent any reconnection. ◆◆ Check the system for a zero-voltage status.
i 7.2 Connecting a tubular motor EN Inputs E1 / E2 (230 V / 50 Hz) , only if required. Connecting the white set cord (SET) from RADEMACHER tubular motors * The white set cord (SET) from RADEMACHER tubular motors must be connected to the neutral terminal [ N ] to ensure trouble-free operation of the tubular motor.
i 8. Assembly EN The Troll Basic DuoFern is designed for flush-mounted installation. For this, you require a 58mm flush-mounted box. We recommend using a deep box. Connecting terminals on bottom > [ 4 ] [2] [1] [5] [3] Installation procedure: 1. Switch off the mains. 2. Make the electrical connection according to the wiring diagram (see page 17). 3. Route the power cables to the flush-mounted box. 4.
i 9. Important information prior to initial commissioning EN IMPORTANT ◆◆ Prior to initial commissioning of the Troll Basic DuoFern, it must be ensured that the end points are configured for the connected tubular motor. ◆◆ If the end points have not yet been configured, it is vital that both end points are configured for the tubular motor, as failure to do so can lead to malfunctions. ◆◆ In order to do so, follow the information provided in the operating manual for the respective tubular motor.
i 10.1 Manual operation (jog mode) EN As soon as Venetian blinds mode is activated with the help of a DuoFern controller (e.g. HomePilot®), it is possible to manually operate the Troll Basic DuoFern in jog mode. Jog mode provides a convenient way to configure Venetian blinds. In doing so, the Venetian blinds motor is powered only as long as the control key is actuated.
11. Logging DuoFern transmitters on / off; brief description EN In order for your Troll Basic DuoFern to react to control signals from the DuoFern network, it is necessary to log each DuoFern device (e.g. DuoFern manual central operating unit, etc.) onto the Troll Basic DuoFern. To do so, please read the operating instructions for the respective DuoFern device. Maximum number of connected devices You can assign a maximum of 20 DuoFern devices to a single Troll Basic DuoFern.
11.1 Login for DuoFern transmitters 1. + EN Activate login mode. Simultaneously press and hold the buttons for approx. 4 seconds. The timer LED flashes green: Login mode remains active for approx. 120 seconds. 2. Switch the desired DuoFern transmitter to login mode. 3. Pay attention to the timer LED. Flashes green Login mode is active. green (for 5 seconds) Login was successful. Afterwards, the LED will light up red again, if the automatic timer has been activated.
11.2 Logging off DuoFern transmitters 1. + EN Activate logout mode. Simultaneously press and hold the buttons for approx. 4 seconds. The timer LED flashes red: Logout mode remains active for approx. 120 seconds. 2. Switch the desired DuoFern transmitter to logout mode. 3. Pay attention to the timer LED. flashes red Logout mode is active. green (for 5 seconds) Log off was successful. Afterwards, the LED will light up red again, if the automatic timer has been activated.
11.3 Clearing the DuoFern network EN This function enables you to log off all DuoFern transmitters from the Troll Basic DuoFern that are no longer accessible via radio. NOTE ◆◆ Not all battery-operated DuoFern transmitters (e.g. the DuoFern manual central operating unit) can be logged off in this way. ◆◆ A software reset must be carried out in order to logout and delete all DuoFern transmitters (see page 37). + 1. + Activate the clear function.
i 12. Automatic mode; brief description EN The Troll Basic DuoFern features four automatic modes which can be switched on/off individually on the device. ◆◆ Automated solar function ◆◆ Automatic timer ◆◆ Automatic dusk function ◆◆ Automatic dawn function The automatic functions are only available if the Troll Basic DuoFern is operated with a respective controller (e.g. HomePilot®, DuoFern manual central operating unit, etc.) (see page 21).
i 13. Set the motor running time EN In order to be able to use all of the functions, such as ventilation position and sunshine position, it is vital that the motor running time is correctly configured beforehand. The running time can be configured directly with the Troll Basic DuoFern or you can enter it in the central DuoFern controller (e.g. HomePilot®). NOTE ◆◆ Tubular motor running times can vary depending on temperature.
i 13.2 Time the running duration of the motor and enter it into the DuoFern controller EN 1. Subsequently move the roller shutters to the upper end point and make a note of the time required. 2. Enter the noted time in the central DuoFern controller (e.g. HomePilot®). NOTE ◆◆ As soon as the motor running time is transferred from the central DuoFern controller to the Troll Basic DuoFern, you will receive confirmation from the system by way of the roller shutter briefly starting up. 14.
14.1 Switching the automated solar function on/off EN The automated solar function enables brightness-dependent control of your roller shutters. The control signals for this function are provided by a light sensor on the DuoFern network. When the automated solar function is triggered, your roller shutters will then lower to the configured sunshine position. Once the solar program is ended, the roller shutters move completely up to the upper end point. 1. Press and hold the solar button for approx.
15. Switching the automatic timer on/off EN Execution of control signals from the DuoFern network. If the automatic timer is activated, control signals for opening and closing times will be received from the DuoFern network and executed by the system. NOTE ◆◆ Executing a random function. If the Troll Basic DuoFern receives a control signal from a DuoFern transmitter with activated random function (e.g. from a HomePilot®), then it is also able to execute the random function.
16. Switching the automatic dusk function on/off EN The automatic dusk function causes the roller shutters to close automatically to their lower end point or the configured ventilation position (see page 33). The control signals for this function are provided by a DuoFern transmitter on the DuoFern network. 1. Press and hold the dusk button for approx. 1 second. 2. Pay attention to the dusk LED. OFF The automatic dusk function is switched off. ON The automatic dusk function is activated. 17.
18. Automatic wind function; brief description EN This function enables you to use the Troll Basic DuoFern to operate, for example, connected Venetian blinds or awnings in relation to the weather conditions. The automatic wind function can also be switched on/off by an overriding DuoFern controller (e.g. HomePilot®). As soon as an external "wind" signal transducer is detected, the control signal can be transferred from the DuoFern network on the Troll Basic DuoFern.
19. Rain function; brief description EN This function enables you to use the Troll Basic DuoFern to operate, for example, a connected awning in relation to the weather conditions. The automatic rain function can also be switched on/off by an overriding DuoFern controller (e.g. HomePilot®). As soon as an external "rain" signal transducer is detected, the control signal can be transferred from the DuoFern network on the Troll Basic DuoFern.
i 20. Set the ventilation position EN If you do not want the roller shutters to close fully to the lower end point, you can use this function to configure an arbitrary position (e.g. as ventilation position). ◆◆ When closing automatically, the roller shutters will stop at the ventilation position, however, they can subsequently be closed completely via manual operation. ◆◆ The ventilation position can be changed at any time.
i 21. Venetian blinds mode; brief description EN This function enables you to use the Troll Basic DuoFern to control Venetian blinds. The Venetian blinds mode can also be switched on/off by an overriding DuoFern controller (e.g. HomePilot®).
i 22. Switching reversal of rotation direction on/off EN It is not necessary to re-wire the motor if the direction of rotation for the connected motor is wrong [ Up ] key moves the roller shutters downwards and [ Down ] key moves the roller shutters upwards). The direction of the motor can be easily changed using the reversal of rotation direction function. 1. 2. + Simultaneously press and hold both buttons for approx. 4 seconds. The solar LED flashes red by way of confirmation.
i 23. End point adjustment EN Set the upper end point. 1. + Simultaneously press and hold the buttons. The roller shutters travel up. The solar LED flashes red by way of confirmation. 2. + Release the buttons... ...as soon as the roller shutter achieve the desired position for the upper end point. The roller shutters stop and the upper end point is stored. Set the lower end point. 3. + Simultaneously press and hold the buttons. The roller shutters travel down.
i 24. Function of external inputs E1 and E2 EN The Troll Basic DuoFern features two external inputs E1 (up) and E2 (down) for connecting an external switch. If all automatic functions are deactivated, the inputs will not be taken into consideration by the system. Function in normal mode The mode of operation and order of switching corresponds to manual mode, as described on page 19. 1. Press the up key (E1). The roller shutters travel up. 2. Press the down key (E2). The roller shutters travel down.
i 26. Dismantling EN There is also a risk of fatal electric shocks when dismounting the Troll Basic DuoFern. Follow the safety instructions for electrical connection on page 16. Procedure for dismantling: 1. Switch off the mains. 2. Secure the connector against reconnection and check that the system is de-energised. 3. Carefully remove the operating unit [ 1 ] from the installation housing [ 3 ]. 4. Remove the frame [ 2 ] 5.
i 28. Technical Specifications External dimensions control unit [ 1 ]: Nominal voltage: Max. switching capacity: Standby consumption: Extension inputs: Connection diameter: Installation depth: Permissible ambient temperature: Data retention: Protection class: Transmission frequency: Transmission power: Range: i EN 50 x 50 x 12 mm (according to DIN 49075) 230 V / 50 Hz; 230 V / 60 Hz 8 (4) A µ (Type 1B) < 0.4 W 2 (E1 and E2) 1.5 mm² 32 mm 0 to 40°C permanent II (only for use in dry areas) 434.
i 30. Warranty conditions EN RADEMACHER Geräte-Elektronik GmbH provides a 24-month warranty for new systems that have been installed in compliance with the installation instructions. All construction faults, material defects and manufacturing defects are covered by the warranty. Your statutory warranty claims shall remain unaffected by this warranty.