Installation Guide for ® SecureMesh CONN-2000 Document Number: PL-0689A Preliminary Revision: 0.2 Date: September 10, 2019 Trilliant Holdings, Inc. 401 Harrison Oaks Blvd.
TOC Chapter 1. Safety and Compliance 8 Safety Information 8 Compliance Notices 9 Modification Statement 11 Interference Statement 11 FCC Class A Digital Device Notice 11 Wireless Notice 12 WEEE 12 Disposal of Old Equipment 12 Countries Outside the European Union 13 EU and EFTA Compliance Notices 13 Password Protection 13 Chapter 2. Overview 14 Description 14 Kit and Parts 14 Additional Installation Parts Replacement Parts Chapter 3.
Ethernet Cable Gland 21 Trilliant Pole-mounting Kit 21 PoE Power Injector 22 Accessory Mounting Bracket 23 Band Strap or Hose Clamp 24 Prepare the Surge Suppressor 24 Attach the Surge Suppressor 25 Chapter 4. Mount the Connector 27 Attach the Connector to a Pole 27 Examples of the Mounted Connector 28 Chapter 5.
Index 52
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Proprietary Notice Copyright © Trilliant Holdings Inc. 2019. All rights reserved. This document describes products, software and services (“Products”) of Trilliant Holdings Inc., its subsidiaries, affiliates (collectively, "Trilliant"), and/or its licensors. This document is licensed, not sold.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A How to Contact Trilliant Use the following methods to contact Trilliant: General Company and Solution Information: https;//trilliant.com Trilliant Headquarters: Tel:+1 919.495.6111 Solution and Customer Support Portal: https://support.trilliant.com/ Note: Make all requests for Solution support or RMA processing through the web portal.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Chapter 1. Safety and Compliance Before installing the CONN-2000, read the instructions in this document. This chapter includes information on safety and compliance, the US FCC statement, and guidance on password protection. Safety Information The caution statements, warning conventions, and warning messages in this section apply to this product and manual.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Warning: Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. Warning: This device is designed to be operated in accordance with normal safe operating procedures. These instructions are not intended to supersede or replace existing safety and operating procedures.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Compliance Standard Radio Operation Certifications FCC and Industry Canada Device IDs Safety Description l EN 55032, EN 55035 l FCC Part 15, Subpart C and Subpart E l Industry Canada RSS-Gen, RSS-247 l EN 301 893, EN 300 328 l Various worldwide approvals l FCC ID: TMB-CONN2000 l IC: 6028A-CONN2000 l UL 62368-1, UL 60950-22 l RF Safety Climatic Mechanical Vibration and Shock Enclosure CSA C22 2 No. 62368-1, CSA C22.2 No.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Compliance Standard Environmental Description l Outdoor UV-stabilized plastic l RoHS Compliant Modification Statement Trilliant has not approved any changes or modifications to this device by the user. Any changes or modifications not expressly approved by Trilliant could void the user's authority to operate the equipment. Trilliant n'approuve aucune modification apportée à l'appareil par l'utilisateur, quelle qu'en soit la nature.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Wireless Notice To satisfy FCC and Industry Canada Radio Frequency (RF) Exposure requirements for mobile and base station transmission devices, a separation distance of 65 cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A By disposing of these products correctly, you will help to save valuable resources, and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service, or the point of sale where you purchased the items.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Chapter 2. Overview This chapter describes what the SecureMesh CONN-2000 does, the kit and parts, and supplies needed to install it. Description The CONN-2000 is the Smart Distribution end node element of the SecureMesh Wide Area Network (WAN). It provides Layer 2 Ethernet transport at air data rates up to 270 Mbps.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A l l l Ethernet surge suppressor: Citel: 521-R0655-01 IEEE802.3af compliant Power over Ethernet (PoE) injector: Tycon TP POE 48GD (Trilliant part # 409-0080-00) For mounting the CONN-2000 on horizontal and vertical poles with an outside diameter between 2 and 9 inches: l l Wall mounting accessory bracket: HM-0395A Worm-type hose clamp, 1/2 inches in width. The diameter should be large enough to accommodate the pole and arrestor’s flange.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Chapter 3. Prepare for Installation This chapter provides information on preparing the CONN-2000 for installation.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Note: Radio performance and coverage typically improves as the height increases. l l l The radio signals to and from the CONN-2000, within the Fresnal zone, will not be obstructed. Any nearby structures do not block line of sight radio coverage. Clear of thick trees or brush at installation site. The site must be maintained free of trees in the foreseeable future. Note: Foliage in the line-of-sight to other devices can degrade radio performance.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Guidelines To ensure optimal reliability, properly ground the surge suppressors. Use a 10 AWG or larger wire to connect it to the ground point on the structure. Figure 2 shows a typical installation with ground wires at the surge suppressors (see #2 and #4 Figure 2; both needing grounding or earthing. Your installation may vary.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A The three most common earth ground points include the following: 1. The primary ground point or down lead provided by the existing ground system at the site, such as a part of the utility pole structure (see Figure 2). 2. A copper-clad ground rod, 10 ft (3 m) or longer, driven into the earth. At a tower with multiple legs, there typically is one ground rod at each leg and a ground wire loop that connects the rods. 3.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Status Checklist Item Description surge suppressor to the ground system on the utility pole or building. Use a 10 AWG or larger down-lead. Outdoor Ethernet Cable When installing the outdoor Ethernet cable, use the UVprotected, STP, CAT5e (or better) cable that includes a properly terminated drain wire. l l In Figure 2 cable segments #5 and #7 do not need to be shielded.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Ethernet Cable Gland One Ethernet cable gland. In Figure 4 it is shown dismantled, with all parts. Figure 4: Dismantled Ethernet Cable Gland Trilliant Pole-mounting Kit The pole-mounting kit comes in a box, as shown in Figure 5 below. The following stainless steel parts are included in the pole-mounting kit: 1. Qty. 2 M6 flat washers 2. Qty. 4 M6 x 10 mm hex head bolts 3. Qty. 2 M6 self-locking nuts 4. Qty. 4 M6 size lock washers 5.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Figure 5: Pole-mounting Kit PoE Power Injector The CONN-2000 is powered using the standard 802.3af PoE. You can use either: 1. A standalone PoE injector sold separately by Trilliant, or 2. An existing standard PoE switch, if available, at the location. Note: Ensure that the PoE unit is 802.3af compliant, or has a higher capacity.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Accessory Mounting Bracket For horizontal and vertical poles with an outside diameter between 2 and 9 inches, and accessory bracket is available. The accessory bracket is designed to fit with the Lbracket, and attach using a band strap. This is not included in the kit. Figure 7: Accessory Mounting Bracket Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Band Strap or Hose Clamp Use the band strap or hose clamp together with the accessory bracket. This is a standard part carried by many installation contractors, and is not supplied in the CONN2000 kit. Figure 8: Band Strap Example Prepare the Surge Suppressor Trilliant recommends installing a surge suppressor on the RJ45 port, near the device. In many installations, a second surge suppressor may be used at the facility entrance.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A 1. If a connector cover is present on the cable, remove it. 2. With a sharp tool such as an Exacto knife, make a small hole like an “x” in the black gasket of the suppressor. Note: Ensure the hole is only large enough for the wires to feed through, and is snug. If the hole is not snug, ants or small bugs might enter and create a nest, which can cause future issues.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A 2. If used, mount the ground clamp on the pole, just below the surge suppressor. 3. Mount the surge protector with two hose clamps. The surge suppressor is designed to attach to a vertical pole that could vary in diameter. The suppressor attaches using two standard hose clamps that fit inside the grooved sections at the top and bottom of the housing.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Chapter 4. Mount the Connector This chapter includes the steps to mount the CONN-2000 to a pole, and examples. Attach the Connector to a Pole 1. Attach the L-bracket to the CONN-2000, using the four hex head bolts and lock washers supplied in the hardware kit (see Figure 3 and Figure 5). 2. Affix the U-bolt and serrated gripper for the CONN-2000 through the slots in the fixed part of the adjustable L-bracket, as shown in Figure 11. 3.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A 6. Ensure there is a drip loop between the surge suppressor and the CONN2000. l Keep the length of cable #1 (see Figure 2) to a minimum while forming a drip loop between the CONN-2000 and the surge suppressor. 7. Attach the ground wire from the surge protector to the ground clamp or the site ground point. Note: The maximum allowable total Ethernet cable length should not exceed 330 ft. (100 m).
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Figure 12: The CONN-2000 Mounted on a Pole (side view one) Figure 13: The CONN-2000 Mounted on a Pole, (side view two) Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Figure 14: CONN-2000 Mounted on a Pole with an Accessory Mounting Bracket and a Band Strap Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Chapter 5. Power Up the Connector This chapter covers the steps to provide power to the CONN-2000 and prepare it for normal operation. Functions on the Connector Face Before you begin powering on the device, review the functions on the CONN face, as shown. The numbers in Figure 15 correspond to the descriptions in Table 3 below.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Table 3: CONN-2000 Part Number and Name Number Part Name 1 Breather Vent 2 RJ45 Connector and Gland Nut 3 Power Indicator 4 LAN Active Indicator 5 WAN Active Indicator 6 RSSI Indicator 7 Reset Push Button Configuration and Startup When the CONN-2000 receives power, the power-on sequence starts automatically. The Status, LAN, WAN, and RSSI LEDs indicate the progress through the sequence.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A l l Power-on mode: Upon connecting to the power supply, the Status, LAN, WAN, and RSSI LEDs flash white in unison. Then, one at a time in sequence, the LEDs flash from blue to green. When the Status and RSSI LEDs are steady and green, the device is linking to the wireless network and actively communicating, or it is already linked. See Table 4 for more information on each status.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Additional Information l l When the device is set up and is functioning normally, the signal may fluctuate. Feedback from other outdoor devices may hinder a good connection. Alignment mode times out after 20 minutes, and the LEDs revert back to normal operation. This does not impact the link establishment in any way. All active links are maintained. Warning: After two hours, the LED indicators stop displaying, as if in sleep mode.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A LEDs There are four LED functions; Status, LAN, WAN, and RSSI (Receive Signal Strength Indicator). Table 4 lists the function, colors, device states and status that the LEDs indicate. Table 4: LED Functions for Normal Operating Mode Function Color(s) LED State Condition / Status Status Green or Red Off Power is off. On green Power is on; normal operation. On green Cold threshold cycling from off to on.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Function Color(s) LED State Condition / Status WAN Blue or Red Off Disconnected from parent device; offline. Flashing blue at 0.33 Hz* or once every 3 seconds. Non-operational state. Flashing blue at 1 Hz or once every second. Pre-authorization state. Flashing blue at 4 Hz* or 4 times every second. Standby operational state. On solid blue Parent device connected. Active link established. On red Provisioning or authorization failure.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Reset Functions You can find the reset button on the Trilliant logo, on the front of the device, as shown in Figure 17. Figure 17: The Reset Button The reset button has different capabilities, such as: l Turn on/off the antenna alignment mode l Reboot the device l Reset the CONN-2000 to factory defaults If it fails to communicate with other devices, press the reset button.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Amount of Time to Press and Release the Reset Switch Action Notes The other three LEDs indicate RSSI level in 3 dB steps. Remove from antenna alignment Press for < 2 seconds and release Reboot Press for 5 - 15 seconds Reset to factory defaults and reboot Press for 30+ seconds Accessing the CLI using WiFi The CLI interface to the CONN-2000 is provided by an internal WiFi module.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Table 6: show wifi Command Description show wifi Shows the current WiFi configuration and status information. Configuration Description Interface Indicates whether the WiFi interface is enabled or disabled. SSID Indicates the string of alphanumeric character that specifies. PSK Indicates the string of plain-English passphrase characters that specifies the Pre-Shared Key which must be between 8 and 63 characters long.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Command Description Firmware Version Indicates the firmware version of the WiFi module. Synopsis show wifi [config | status] Table 7: show prov wifi Command Description show prov wifi Shows the flash WiFi settings. Configuration Description Interface Indicates whether the WiFi interface is enabled or disabled.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Command Description Synopsis show prov wifi Table 8: set wifi Command Description set wifi Sets the current WiFi settings. Configuration Description Interface Indicates whether the WiFi interface is enabled or disabled. SSID Indicates the string of alphanumeric character that specifies the Service Set IDentifier which can be at most 32 characters long.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Table 9: set prov wifi Command Description set prov wifi Sets the flash Wifi settings. Configuration Description Interface Indicates whether the WiFi interface is enabled or disabled. SSID Indicates the string of alphanumeric character that specifies the Service Set IDentifier which can be at most 32 characters long.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Steps Use the following steps to access the CLI using WiFi. Note: These steps assume that you are connecting to a CONN-2000 configured with factory default WiFi settings. 1. From a client WiFi device, search for an SSID with the default value of "Trilliant." 2. Connect to the Trilliant SSID using this security key: Trilli@ant: l Example: Trilli@nt:000adb123456 3. Wait for the WiFi connection to be established. 4.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Chapter 6. Specifications and Pinout This chapter provides reference information for the CONN-2000, including specifications and pinout standard. Specifications When planning for an installation, use the following specifications: l Dimensions 11.0 in. (28 cm) H x 11 in. (28.0 cm) W x 6.8 in. l Weight 3.7 lb. (1.68 kg) Pinout This product uses 802.3af/at standards. The device can be powered by any compliant Power over Ethernet (PoE).
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Table 10: Signals and Pins for the RJ45 Connector PIN Cable Pairing 10/100base-T 1000base-T 1 Orange/White TRP1(+) TRP1(+) 2 Orange TRP1(-) TRP1(-) 3 Green/White TRP2(+) TRP2(+) 4 Blue PoE(+) TRP3(+) / PoE(+) 5 Blue/White PoE(+) TRP3(-) / PoE(-) 6 Green TRP2(-) TRP2(-) 7 Brown/White PoE(-) TRP4(+) / PoE(-) 8 Brown PoE(-) TRP4(+) / PoE(-) Shield Oveall Shield Earthed in Arrestor Earthed in Arrestor Note: 10/100ba
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Appendix A. RJ45 Cable Assembly This appendix provides information on the RJ45 cable assembly. Use the steps below to prepare the RJ45 cable to be inserted into the plug housing and then crimp. Assembly Steps 1. Prepare the end of the cable by first stripping back the outer jacket to expose one of the conductors. Figure 18: The Stripped Outer Jacket 2. Fold back the shielded braid and drain wire, so that they lay flat over the outer jacket. 3.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Figure 19: The Plug's Grounding Clip 5. Ensure the pairs of the conductors are ordered as they should be. Then slide them onto the conductor spacer. Figure 20: The Pairs of the Conductors on the Conductor Spacer 6. Trim the conductors so that the tips are exposed to the jacket at 0.6 in. 7. Twist and fold back the braid and drain the wires. 8. Align the wires to insert them into the plug housing.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Figure 21: Aligning the Wires to Insert into the Plug Housing 9. Insert the wires into the plug housing with the flange of spacers facing up. 10. Then crimp the wires using the HTS2700 tool. a. Place the braid and drain wires on the back side of the cables in the strain relief saddle. b. Straighten the strain relief to form a straight exit path. Figure 22: Crimping the Cable Strain 11. The RJ45 cable assembly is complete.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Figure 23: The Completed RJ45 Cable Assembly Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents may not be used or disclosed without the express written consent of Trilliant.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Glossary E EFTA European Free Trade Association EMC Electromagnetic Compatibility EU European Union F FCC Fedral Communications Commission P PoE Power over Ethernet R RF Radio Frequency Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A W WAN Wide Area Network WEEE Waste Electrical and Electronic Equipment Directive Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Index A Accessory mounting bracket 23 Alignment 33 Attach surge suppressor 25 B Band Strap 24 C Cold startup 33 Commission 31 Compliance 8 Components 20 Ethernet cable gland 21 L-bracket 20 Pole-mounting kit 21 Configuration Startup 32 CONN-2000 1, 14 Alignment 33 Commission 31 Configuration 32 Examples 28 Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A Functions Reset 37 Kit 14 LEDs 35 Mount 27 Other Parts 14 Other Supplies 14 Parts 14 Pinout 44 Replacement Parts 15 Reset switch 37 Specifications 44 Startup Cold startup 32 PoE Injector 32 E Ethernet cable gland 21 European Free Trade Association (EFTA) 13 European Union (EU) 13 Examples 28 F FCC Class A Digital Device Notice 11 Functions 31 Notice: The contents of this document are proprietary and confidential and the property of Trilliant Hold
Installation Guide for SecureMesh® CONN-2000 - PL-0689A G Grounding 17 Grounding checklist 19 Grounding guidelines 18 Grounding requirements 17 H Hose Clamp 24 I Installation Location requirements 16 Prepare 16 Tools 16 L L-bracket 20 LEDs 35 M Mount CONN-2000 27 Mount to pole 27 Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A O Old equipment 12 Overview 14 P Password 13 Pinout 44 PoE power injector 22, 32 Pole-mounting kit 21 R Reset functions 37 Reset switch 37 RJ45 cable assembly 46 S Safety warnings 8 Specifications Pinout 44 Surge suppressor Attach 25 Prepare 24 Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors.
Installation Guide for SecureMesh® CONN-2000 - PL-0689A W Warnings 9 WEEE 12 WiFi Access CLI 38 set prov wifi 42 set wifi 41 show prov wifi 40 show wifi 39 Steps 43 Wireless Notice 12 Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant.