38
Installation Guide for SecureMesh
®
CONN-2000 - PL-0689A
Action
Amount of Time to
Press and Release the
Reset Switch
Notes
The other three LEDs indicate
RSSI level in 3 dB steps.
Remove from
antenna alignment
Press for < 2 seconds and
release
Reboot Press for 5 - 15 seconds
Reset to factory
defaults and reboot
Press for 30+ seconds
Accessing the CLI using WiFi
The CLI interface to the CONN-2000 is provided by an internal WiFi module. The mod-
ule enables a WiFi connection to the CONN-2000 using a Service Set Identifier/Pre-
Shared Key (SSID/PSK). After establishing a connection via WiFi, a Telnet con-
nection can be opened by using a pre-configured IP address as described in the fol-
lowing tables (Table 6, Table 7, Table 8, and Table 9).
Use the following list of commands to configure the Serial to WiFi parameters manu-
ally, to change the active configuration, and or the persistent configuration.
Note: Changing the active configuration will cause the Serial to WiFi
module to reset.