TReX User Manual v2.14 Firmware
*OUT_CONFIG=1:1,0<CR>
*OUT_CONFIG=2:1,0<CR>
Scenario 1: To turn output 1 ON and turn OFF output 2;
Message payload:
[[Unit_A]1-2]
Scenario 2: To turn output 2 ON and turn OFF output 1;
Message payload:
[[Unit_A]2-1]
Scenario 3: To turn output 1 and 2 ON;
Message payload:
[[Unit_A]12-]
Scenario 4: To turn output 1 and 2 OFF;
Message payload:
[[Unit_A]-12]
Consider that we have several TReX Units and each one is configured with a different
OUT_ID; “Unit_A”, “Unit_B” and “Unit_C”
Scenario 5: To turn output 1 and 2 ON in the Unit_A:
Message payload:
[[Unit_A]12-]
Scenario 6: We want:
to turn output 1 and 2 ON in the Unit_A,
to turn output 1 ON and turn OFF output 2 on the Unit_B,
turn OFF output1 and 2 on the Unit_C;
Message payload:
[[Unit_A]12-] [[Unit_B]1-2] [[Unit_C]-12]
Analog & Digital Output Format
The WTE output control protocol allows the direct control of analog outputs.