TReX User Manual v2.14 Firmware
*RSSI
Returns the receiver signal strength in -dBm. (returns between 0 and -130).
Usage:
*RSSI<CR>
*USERPASS
Sets the web and TCP user and password. User must be at least 3 letters and password must be
at least 4 letters. These credentials are requested for each new web and TCP connection.
Typical usage:
*USERPASS=admin:TReX<CR>
When prompted for a login when using a TCP connection (not through web browser), login
with the full user and password together.
e.g. in response to “login:”
enter
“admin:TReX”
The TReX will immediately report if successfully logged in.
To completely disable all web and TCP connection user and passwords, enter
*USERPASS=none:none<CR>
*SAVE<CR>
By default the user and password is set to “none:none
*IO
Returns all input and output states.
Typical usage:
*IO<CR>
Typical output:
IO=I:01000000--- O:00000000 ADC:257,252 DAC:0,0
In this typical output, there are 11 inputs shown. First 8 are the digital inputs. The 9
th
input is
1 or 0 based on battery high/low thresholds set. Inputs 10 and 11 are ADCs, again displayed
as 1 or 0 based on set thresholds. The ‘-’ is shown when the input level is unknown, such as
when an input is between the high and low configured thresholds. Output states for all 8
outputs follow, then ADC inputs 1 and 2 and finally the current DAC settings.
© WTE Limited, 2018 – Christchurch New Zealand Page 65 of 158