8.8 RF_SecFlags: Modify the security settings
Settings
index
Designation
Permissible
values
Default value
Permissions
Number
of Bytes
12
RF_SecFlags
See
description
0
read/write
1
This 8-Bit field configures security settings of the module. Chapter
5.4
contains further
information about secure connections.
When connecting from a Proteus-III to another Proteus-III, be sure that the
same security mode is used.
When connecting from a foreign device to a Proteus-III, the peripheral
(Proteus-III) determines the minimum security level needed for communica-
tion. So configure the
RF_SecFlags
of the peripheral to set the desired security
level.
When updating this user setting (like enabling bonding or changing the se-
curity mode) please remove all existing bonding data using the command
CMD_DELETEBONDS_REQ
.
Proteus-III reference manual version 0.11 © November 2019