Reference Manual

Table Of Contents
Knowing the connection interval and the number of messages that will be sent, the time
necessary to setup a connection can be estimated by multiplying the number of messages
with the connection interval.
In case the Device Information Service is enabled, the number of messages
and thus the time consumption of the connection setup may be increased.
9.4 Connection based data transmission
After setting up a connection, data can be transmitted using the
CMD_DATA_REQ
. It buffers the
data in the module and sends it with the next connection interval event. As soon as the data
has been transmitted successfully, a
CMD_TXCOMPLETE_RSP
is returned by the UART. The time
needed for this coincides with the connection interval that was negotiated during connection
setup. The
RF_ConnectionTiming
parameter defines the minimum and maximum connection
interval, which is supported by the module.
Proteus-III reference manual version 0.11 © November 2019
www.we-online.com/wireless-connectivity 161