Reference Manual

Table Of Contents
Info Module A Module B
Request
CMD_DATA_REQ
: Send "EFGH" to
module B
02 04 04 00 45 46 47
48 0E
Response
CMD_DATA_CNF
: Request received,
send data now
02 44 01 00 00 47
Indication
CMD_DATA_IND
: Received string
"EFGH" from
FS_BTMAC
0x55 0x00 0x00 0xDA
0x18 0x00 with RSSI of 0xC1 (-63dBm)
02 84 0B 00 55 00
00 DA 18 00 C1 45
46 47 48 D7
Response
CMD_TXCOMPLETE_RSP
: Data
transmitted successfully
02 C4 01 00 00 C7
6. Now module A closes the connection, so both modules will get a disconnect indication.
Info Module A Module B
Request
CMD_DISCONNECT_REQ
: Disconnect 02 07 00 00 05
Response
CMD_DISCONNECT_CNF
: Request
received, disconnect now
02 47 01 00 00 44
Indication
CMD_DISCONNECT_IND
: Connection
closed
02 87 01 00 16 92
Indication
CMD_DISCONNECT_IND
: Connection
closed
02 87 01 00 F3 97
Proteus-III reference manual version 0.11 © November 2019