Reference Manual

Table Of Contents
Start signal Command | 0x40 Length Status CS
0x02 0x42 0x01 0x00 1 Byte 1 Byte
Status:
0x00: Request received, will go to sleep now
0x01: Operation failed
0xFF: Operation not permitted
Please note that the WAKE_UP pin has a second function. If the mod-
ule is not in
ACTION_SLEEP
mode and the UART was disabled using the
CMD_UARTDISABLE_REQ
, the UART can be re-enabled by applying falling edge,
holding the line low for at least 10ms before applying a rising edge and
holding it high for at least 10ms. In this case the module answers with a
CMD_UARTENABLE_IND
message.
7.5.4 CMD_SLEEP_IND
This indication is send by the module when the
RF_AdvertisingTimeout
has expired without
a connection to the module.
Format:
Start signal Command Length Status CS
0x02 0x82 0x01 0x00 0x00 1 Byte
Status:
0x00: Advertising timeout detected, will go to sleep now
7.5.5 CMD_FACTORYRESET_REQ
This command triggers a factory reset of the module. First, the default User Settings are
restored, then the module is reset.
Please note that also the GPIO configuration specified in chapter
11
is reset to
default.
Format:
Start signal Command Length CS
0x02 0x1C 0x00 0x00 0x1E
Response (
CMD_FACTORYRESET_CNF
):
Proteus-III reference manual version 0.11 © November 2019
www.we-online.com/wireless-connectivity 80