Operator's Manual

P-2000/C-2000/RT-2000
Operator’s Manual
Page 32 of 39 Publication No. 150-049105
P-2000 Operators Manual Rev. A
Oct 2003
Connect the PC to the data port on the front of the P-2000(RT-2000 not C-2000).
Using the CPS software, read the FM1 and save the file as sent by the Wulfsberg Factory for backup purposes.
Perform any changes to the archive file such as adding/deleting channels, changing encryption options etc. For
the P-2000 to function properly DO NOT change key button options or display options. Also, the
Zone/Channel assignment must be made so that there no more than 16 channels per zone.
Once all new channels have been entered, transfer the updated archive back into the P-2000. The Motorola
software will indicate successful completion of this task.
Perform the above actions on both FM1 and FM2.
Press the HOME button once to enter the LEARN MODE. In this mode, the P-2000 computer interrogates the
internal transceivers to determine what changes have been made and to update its internal memory. This
process can take several minutes. The operator will be shown progress as the system completes its task. This
task must be successfully performed or the P-2000 main processor will not be able to properly function with the
internal transceivers.
Upon successful completion of the LEARN mode, press the HOME button several times to return to the HOME
page.
You can always get back to the HOME PAGE by pressing the HOME
button one or more times.