User's Manual

FLEXCOMM II
C-5000 (P-25 Capable)
Operator’s Manual
S Y S # 1 : 2 = N E X T 3 = B A C K
R A D I O M O D E = 1
(4) This page will only display if the RT-5000 part number entered indicates an ITM is present.
Use the cursor/value knobs to select a value of 1 or 2. Mode 1 indicates that the ITM should
act as part of the main transceiver, i.e. the two transceivers appear to be a single unit. Mode
2 indicates that the ITM should not act as part of the main, i.e. it should behave as a Guard
receiver. Press the MODE button to display the next menu page.
S Y S # 1 : 2 = N E X T 3 = B A C K
Z O N E MODE = SIN G L E
(5) This page will only display if the RT-5000 part number entered indicates an ITM is present.
Use the cursor/value knobs to select a value of SINGLE or MULTI. SINGLE indicates that
the ITM is configured for single-zone mode, which means all channels (up to 256) are
programmed in zone 1. MULTI indicates that the ITM is configured for multi-zone mode,
which means channels are dispersed across multiple (up to 16) zones. Press the MODE
button to display the next menu page.
Note:
Software versions 10 and below will not have this feature available.
I N C 2 = N E X T 3 = B A C K
D E C M A I N S Q L = 1 6 0
(6) This page allows you to set the RT-5000’s main receiver squelch level. Press the UPPER
SOFT KEY to increase the squelch level, or the LOWER SOFT KEY to decrease squelch
level. The squelch level determines the signal strength required by the RT-5000 to open its
audio gates, allowing you to hear what it is receiving. The larger the number, the stronger the
required signal. Press the MODE button to display the next menu page.
I N C 2 = N E X T 3 = B A C K
D E C G UARD SQL = 1 6 0
(7) This page allows you to set the RT-5000’s guard receiver squelch level. Press the UPPER
SOFT KEY to increase the squelch level, or the LOWER SOFT KEY to decrease squelch
level. The squelch level determines the signal strength required by the RT-5000 to open its
audio gates, allowing you to hear what it is receiving. The larger the number, the stronger the
required signal. Press the MODE button to display the next menu page.
Publication
No. 150-041102 Page 21 of 88
Rev E C-5000 Operators Manual