Datasheet

Properties Test conditions
Value
Unit
min. typ. max.
Peak Wavelength (Red) 20 mA λ
Peak R
636 nm
Peak Wavelength (Green) 20 mA λ
Peak G
520 nm
Peak Wavelength (Blue) 20 mA λ
Peak B
468 nm
Dominant Wavelength (Red) 20 mA λ
Dom R
622 nm
Dominant Wavelength (Green) 20 mA λ
Dom G
527 nm
Dominant Wavelength (Blue) 20 mA λ
Dom B
470 nm
Luminous Intensity (Red) 20 mA I
V R
45 70 mcd
Luminous Intensity (Green) 20 mA I
V G
180 360 mcd
Luminous Intensity (Blue) 20 mA I
V B
45 80 mcd
Forward Voltage (Red) 20 mA V
F R
1.9 2.4 V
Forward Voltage (Green) 20 mA V
F G
3.3 3.9 V
Forward Voltage (Blue) 20 mA V
F B
3.3 3.9 V
Spectral Bandwidth (Red) 20 mA Δλ R 17 nm
Spectral Bandwidth (Green) 20 mA Δλ G 40 nm
Spectral Bandwidth (Blue) 20 mA Δλ B 40 nm
Reverse Current 5 V I
REV
100 μA
Viewing Angle Phi 0° 20 mA
50%
120 °
Electrical & Optical Properties: Viewing Angle:
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
100
0°
10°
20°
30°
40°
45°
50°
60°
70°
80°
90°
-45-90
Relative Luminous Intensity (%)
- 60°
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
KaS PLD DIN ISO 2768-1m
DESCRIPTION
WL-SFCW SMD Full-color Chip
LED Waterclear
ORDER CODE
150066M173000
SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
0606
001.000 Valid 2016-08-11 eiPal 2/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.