Datasheet
Dimensions: [mm]
1,7 ±0,2
0,9 ±0,1
2,2 ±0,2
3,2 ±0,2
2,8 ±0,2
1,9 ±0,2
0,15 typ.
3,5 ±0,2
O
2,4 ±0,2
1
2
Polarity Mark
1
2
Scale - 7:1
Recommended Land Pattern: [mm]
2,4
1,6 1,25
4,45
1 2
Scale - 7:1
Schematic:
2
-
+
1
Properties Test conditions Value Unit
Power Dissipation P
Diss
175 mW
Peak Forward Current I
F Peak
duty/ 10 @ 1 kHz 150 mA
Continuous Forward Current I
F
50 mA
Reverse Voltage V
REV
5 V
ESD Threshold/ Human Body
Model
V
ESD HBM
1000 V
Absolute Maximum Ratings (Ambient Temperature 25°C):
Chip Technology InGaN
Emitting Color Blue
Lens Type Top LED
Optical Properties:
Operating Temperature -40 up to +85 °C
Storage Conditions (in original
packaging)
< 40 °C ; < 90 % RH
Storage Conditions (for single
parts)
-40 up to +100 °C
Moisture Sensitivity Level (MSL) 3
General Information:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
PLD 001.001 2018-12-11 DIN ISO 2768-1m
DESCRIPTION
WL-SMTW SMT Mono-color TOP
LED Waterclear
ORDER CODE
150141BS73113
SIZE/TYPE BUSINESS UNIT STATUS PAGE
3528 eiPal Valid 1/7
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.