Datasheet

Dimensions: [mm]
0,3 ±0,1
0,5 ±0,1 0,25 ±0,1
0,28 ±0,1
0,55 ±0,1
1,0 ±0,1
2
21
1
Polarity Mark
Scale - 35:1
Recommended Land Pattern: [mm]
0,5 0,5 0,5
1 2
Scale - 35:1
Schematic:
2
+
-
1
Properties Value Unit
Power Dissipation P
Diss
0.1 W
Peak Forward Current I
F Peak
250 mA
Continuous Forward Current I
F
50 mA
Reverse Voltage V
REV
5 V
ESD Threshold/ Human Body
Model
V
ESD HBM
2000 V
Absolute Maximum Ratings (Ambient Temperature 25°C):
Chip Technology AlGaAs
Emitting Color Infrared
Lens Type Sideview Waterclear
Optical Properties:
IR LEDs emit high intensity IR light.
Do not look directly into the LED during operation.
This can be harmful to your eyes.
Wear protective eyewear.
Please follow safety precautions given in
IEC 60825-1 and IEC 62471.
Keep out of reach of children.
Avoid direct eye and skin exposure to LED!
CAUTION – IR
Operating Temperature -40 up to +85 °C
Storage Conditions (in original
packaging)
< 40 °C ; < 90 % RH
Storage Conditions (for single
parts)
-40 up to +85 °C
Moisture Sensitivity Level (MSL) 3
General Information:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
DaSc ZAn DIN ISO 2768-1m
DESCRIPTION
WL-SISW SMT Infrared Sideview
LED Waterclear
ORDER CODE
15404094BA470
SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
0402
001.000 Valid 2018-10-19 eiPal 1/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.

Summary of content (8 pages)