Datasheet

Dimensions: [mm]
2,0 ±0,1 0,75 ±0,1
2,2 ±0,1
3,2 ±0,1
3,5 ±0,1
1,9 ±0,1
2,8 ±0,1
Collector Mark
1
2
2
1
Scale - 8:1
Recommended Land Pattern: [mm]
1,15 2,0 1,15
2,2
2
1
Scale - 8:1
Schematic:
Collector
Emitter
1
2
Properties Value Unit
Power Dissipation P
Diss
150 mW
Collector Emitter Voltage V
CE
35 V
Emitter Collector Voltage V
EC
5 V
Continuous Collector Current I
C
20 mA
ESD Threshold/ Human Body
Model
V
ESD HBM
2000 V
Absolute Maximum Ratings (Ambient Temperature 25°C):
Chip Technology Si
Polarity NPN phototransistor
Lens Type Black
Optical Properties:
Operating Temperature -40 up to +85 °C
Storage Conditions (in original
packaging)
< 40 °C ; < 90 % RH
Storage Conditions (for single
parts)
-40 up to +100 °C
Moisture Sensitivity Level (MSL) 4
General Information:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
DaSc SG DIN ISO 2768-1m
DESCRIPTION
WL-STTB SMT Phototransistor Top
Black
ORDER CODE
1541411NEA210
SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
3528
001.000 Valid 2018-10-24 eiPal 1/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.