Data Sheet
Properties Test conditions
Value
Unit
min. typ. max.
Measurement range P
RANGE
-0.1 0.1 kPa
Absolute accuracy ACC
P_ABS
T = 25 °C -4 %FSS ±2 %FSS 4 %FSS
Total accuracy ACC
P_TOT
T = 0 to 70 °C -5 %FSS ±2.5 %FSS 5 %FSS
Sensitivity (digital) SEN
P
7.63*10
-6
kPa/digit
Sensitivity (analog) SEN
P_AN
0.05 kPa/V
Repeatability ACC
P_REP
±0.1 %FSS
Nonlinearity ACC
P_NL
-0.3 %FSS ±0.1 %FSS 0.3 %FSS
Resolution (ADC) RES
P
15 bits
Resolution (DAC) RES
P_DAC
11 bits
Response time t
RESP
2.2 ms
Long term drift ACC
P_DRIFT
per year ±0.5 %FSS
Pressure Sensor Specification:
Properties
Value
Unit
min. typ. max.
Measurement range T
RANGE
0 70 °C
Sensitivity SEN
T
4.272*10
-3
°C /digit
Resolution (ADC) RES
T
15 bits
Temperature Sensor Specification:
Properties
Value
Unit
min. typ. max.
Operating supply voltage V
DD
4.75 5 5.25 V
Current consumption I
DD
4 6.5 mA
Output current analog pin I
OUT_A
1 mA
Digital input voltage - high-level V
IH
0.7 * V
DD
Digital input voltage - low-level V
IL
0.3 * V
DD
Digital output voltage - high-
level
V
OH
0.9 * V
DD
Digital output voltage - low-level V
OL
0.1 * V
DD
Electrical Properties:
Properties
Value
Unit
min. max.
Input voltage VDD pin V
DD
-0.3 6.5 V
Input voltage control pins
1)
V
IN_MAX
-0.3 5.5 V
Differential over pressure P
OVER
10 kPa
Differential burst pressure P
BURST
10 kPa
Common mode pressure P
CM
2500 kPa
Absolute Maximum Ratings:
1)
Control pins are SDA and SCL
Operating Temperature -25 up to +85 °C
Storage Conditions (in original
packaging)
< 40 °C ; < 75 % RH
Compensated temperature range 0 to 70 °C
Communication interface I
2
C, Analog
Moisture Sensitivity Level (MSL) 1
Electrostatic discharge
protection (HBM)
2 kV
General Information:
Pin Pad Description I/O
SCL 1 I²C serial clock Input
SDA 2 I²C serial data Input/Output
GND 3 Negative supply volage Supply
VOUT 4 Analog output Output
Product Specific Pinning:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
NiM 001.000 2019-08-13 DIN ISO 2768-1m
DESCRIPTION
WSEN-PDUS Differential Pressure
Sensor
ORDER CODE
2513130810001
BUSINESS UNIT STATUS PAGE
eiSos Valid 2/7
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.