Instructions

Table Of Contents
Part number: 2513130810301
Value
Parameter
Symbol
Test conditions
Min Typ Max
Unit
Measurement range
P
RANGE
0 100
kPa
Absolute accuracy
5
ACC
P_ABS
T = 25 °C
-0.3 ±0.1 0.3
%FSS
Total accuracy
6
ACC
P_TOT
T = 0 to 70 °C
-0.5 ±0.25 0.5
%FSS
Sensitivity (digital)
SEN
P
3.815 ×10
-3
kPa/digit
Sensitivity (analog)
SEN
P_AN
25
kPa/ V
Repeatability
7
ACC
P_REP
±0.01
%FSS
Long term drift
ACC
P_DRIFT
±0.05
%FSS
Table 9: Pressure sensor specifications (part nr.: 2513130810301)
Part number: 2513130810401
Value
Parameter
Symbol
Test conditions
Min Typ Max
Unit
Measurement range
P
RANGE
-100 1000
kPa
Absolute accuracy
5
ACC
P_ABS
T = 25 °C
-0.3 ±0.1 0.3
%FSS
Total accuracy
6
ACC
P_TOT
T = 0 to 70 °C
-0.5 ±0.25 0.5
%FSS
Sensitivity (digital)
SEN
P
4.196 ×10
-2
kPa/digit
Sensitivity (analog)
SEN
P_AN
275
kPa/ V
Repeatability
7
ACC
P_REP
±0.01
%FSS
Long term drift
ACC
P_DRIFT
±0.05
%FSS
Table 10: Pressure sensor specifications (Part nr.: 2513130810401)
5. Absolute accuracy includes effects of non-linearity, pressure hysteresis, offset, span and repeatability at
room temperature.
6. Total accuracy includes all effects of offset, non-linearity, pressure hysteresis, span, repeatability and
thermal effects between the compensated temperature range 0°C and 70 °C.
7. Repeatability is the typical deviation of the sensor output after 10 pressure cycles.
Differential Pressure Sensor, Part Nr. 25131308xxx01
User manual version 1.0 © August 2019
www.we-online.com/sensors 12