4 Digital interface
The sensor supports standard I
2
C (Inter-IC) bus protocol. I
2
C is a serial 8-bit protocol with
two-wire interface that supports communication between different ICs, for example, between
microcontrollers and other peripheral devices. Further information about the I
2
C interface
can be found at https://www.nxp.com/docs/en/user-guide/UM10204.pdf .
4.1 General characteristics
A serial data line (SDA) and a serial clock line (SCL) are required for the communication
between the devices connected via I
2
C bus. Both SDA and SCL lines are bidirectional. The
output stages of devices connected to the bus must have an open-drain or open-collector.
Hence, the SDA and SCL lines are connected to a positive supply voltage via pull-up resis-
tors. In I
2
C protocol, the communication is realized through master-slave principle. A master
device generates the clock pulse, a start command and a stop command for the data trans-
fer. Each connected device on the bus is addressable via a unique address. Master and
slave can act as a transmitter (master-transmitter or slave transmitter) or a receiver (master
receiver or slave receiver) depending upon whether the data needs to be sent or received.
This sensor behaves like a slave device on the I
2
C bus
Microcontroller
(Master)
R
p
R
p
Sensor
(Slave-1)
Sensor
(Slave-2)
+VDD
SCL
(serial clock)
SDA
(serial data)
Pull up resistors
Figure 3: Master-slave concept