Datasheet

Cover Material Stainless Steel
Actuator Material Silicone Rubber
Actuator Flammability Rating UL94 HB
Actuator Color White
Frame Material HTN
Frame Flammability Rating UL94 V-0
Frame Color Black
Contact Material Stainless Steel
Contact Plating Silver
Terminal Material Copper Alloy
Terminal Plating Silver
Material Properties:
Properties Test conditions Value Unit Tol.
Rated Current I
R
50 mA
Rated Voltage U
R
12 V (DC)
Contact Resistance Initial R 100 max.
Contact Resistance After Life
Test
R 2 Ω max.
Insulation Resistance 500 V (DC) R
ISO
100 min.
Withstanding Voltage 1 min 250 V (AC)
Bounce 10 ms max.
Electrical Properties:
Properties Value Unit Tol.
Operation Force 160 g ±60g
Life Cycle 1000000 Times
Stroke 0.4 mm ±0.2mm
Mechanical Properties:
Operating Temperature -40 °C up to +85 °C
Storage Temperature (in original
packaging)
-40 °C up to +85 °C
Washable Yes
General Information:
Packaging Tape and Reel
Packaging Properties:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
DaSc eLin DIN ISO 2768-1m
DESCRIPTION
6 x 6 mm J-Hook SMD Hermetic
Tact Switch WS-TASV
ORDER CODE
430783051816
REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
001.003 Valid 2018-01-18 eiCan 2/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.