WERI Mini Applicator
I:\Specs\eiCan\WERI\ConTOOLC\Datasheet\User's Manual_WERI Mini Applicator.docx
7 Adjustments
Any adjustment must be performed after having made sure that the press is turned
off.
7.1 Crimping heights (trained operator)
Both A (top) and B (bottom) adjusting rings must be set with reference to the C mark.
7.1.1 Conductor crimping height
The A adjusting ring has a setting range of 2.7 mm with a resolution of 0.01 mm, and an INDEX of
1.40 corresponds to 14 on the ring.
If the INDEX is 1.45, the ring must be set to 14 and then 5 more steps are necessary. Indeed,
1.40 + 5 × 0.01 = 1.45.
A crimping test can now be done and carefully measured: depending on the result, the adjusting
ring has to be turned either clockwise (lower crimping height) or counter-clockwise (higher crimping
height).
NOTE: this final fine adjustment is needed because the user’s press is different from the one that
was used to develop the mini applicator.
7.1.2 Insulation crimping height
Set the B adjusting ring to its minimum and turn it clockwise until the crimping is deemed correct.