9 Maintenance (trained operator)
9.1 Cleaning and lubrication
The mini applicator must be cleaned and lubricated every time it is removed from
the press or every 8 working hours.
Suggested lubricating grease: DIN 51502 KP 2 K-30.
Remove the mini applicator from the press.
Remove the ram from the mini applicator.
Using a clean cloth, remove any grease or contamination from the ram.
Check the anvils, punches and cutters, and replace worn or damaged parts.
Clean the mini applicator body carefully.
Lubricate the ram and mini applicator body, together with all moving part.
Put the ram back into the body, spray the mini applicator with a protective oil and, if the mini
applicator is not immediately used, reinstall the protective rubber spacer.
Every month fully clean the mini applicator using degreasing products which do not
damage plastic parts or surface finishes. Remove the counter if you wash the mini applicator by
immersion or by means of liquid under pressure.
Always lubricate the ram and all the sliding parts before putting the mini applicator back to use.
To correctly maintain the mini applicator, its cycles should be recorded, in order to plan the
replacement of the key components.
When replacing worn parts, the operation should be recorded: this will assist in scheduling
preventive maintenance and the ordering of spare parts
9.2 Storage
When the mini applicator isn’t used for a long period, remove it from the press and clean it. Before
storing it, spray the applicator with a thin layer of protective oil.