Datasheet

Properties Value Unit
Cable RG-316/U
Nominal Outer Cable Diameter 2.49 mm
Material Properties Cable:
Insulator Material PTFE
Insulator Color White
Center Contact Material Brass
Center Contact Plating Gold, min. 0.76µm over Nickel
Body Material Brass
Body Plating Gold, min. 0.076µm over Nickel
Coupling Nut Material Brass
Coupling Nut Plating Gold, min. 0.076µm over Nickel
Retention Ring (C Ring) Material Stainless Steel
Retention Ring (C Ring) Plating Passivated
Gasket Material Silicone
Gasket Color Red
Ferrule Material Brass
Ferrule Plating Gold, min. 0.076µm over Nickel
Heat Shrink Tube Material PE
Heat Shrink Tube Color Black
Material Properties Connector 1:
Insulator Material PTFE
Insulator Color White
Center Contact Material Beryllium Copper
Center Contact Plating Gold, min. 0.76µm over Nickel
Body Material Brass
Body Plating Gold, min. 0.076µm over Nickel
Ferrule Material Brass
Ferrule Plating Gold, min. 0.076µm over Nickel
Heat Shrink Tube Material PE
Heat Shrink Tube Color Black
Nut Material Brass
Nut Plating Gold, min. 0.076µm over Nickel
Lock Washer Material Brass
Lock Washer Plating Gold, min. 0.076µm over Nickel
Material Properties Connector 2:
Interface MIL-STD-348
Cable Type Flexible
Cable Shielding Braid
Connector Type 1 SMA
Gender 1 Plug
Orientation Type 1 Straight
Connector Type 2 SMA
Gender 2 Jack
Orientation Type 2 Straight
Kind Properties:
Operating Temperature -55 °C up to +165 °C
Compliance RoHS
General Information:
Properties Test conditions Value Unit Tol.
Impedance DC~6 GHz Z 50 Ω
Frequency Range f DC~6 GHz
VSWR DC~6 GHz 1.5 max.
Insertion Loss DC~6 GHz IL 1.2 dB max.
Electrical Properties:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
DaSc JaC DIN ISO 2768-1m
DESCRIPTION
SMA Straight Plug to SMA Straight
Bulkhead Jack on Flexible Cable
RG316 WR-CXASY
ORDER CODE
65503503230505
REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
001.001 Valid 2018-05-24 eiCan 2/5
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.