Datasheet
Packaging Specification - Tape: [mm]
Start
End
Feeding direction
NB: Actual packaging may slightly differ from datasheet
D0
B0
P2
P0
E
P1D1
W
F
S
Carrier Tape
A0
T1
T2
K0
T
Top Cover
Tape
Cover Tape
No Component
min. 160mm
Components No Component
min. 100mm
Cover Tape
min. 400mm
A
A
Packaging is referred to the international standard IEC 60286-3:2019
A0 B0 W T T1 T2 K0 P0 P1 P2 D0 D1 E S F Tape Type 3 VPE / packaging unit
typ. typ. +0.3/-0.3 max. max. max. typ. ±0.1 ±0.1 ±0.15 +0.1/ -0 min. ±0.1 ±0.1 ±0.1 pcs.
29.3 30.1 44 1 0.1 4.8 3.8 4 36 2,0 1.5 2,0 1.75 40.4 20.2 Polystyrene 400
Pull-of force
Tape width
44 mm
0,1 N - 1,3 N
1
6
5
°
-
1
8
0
°
Packaging Specification - Reel: [mm]
B
D
C
W1
close to center
W3
W2
N
A
detail B
Cover Tape
Chip Cavity
Sprocket Hole
Embossment
B
A
(mm)
B
(mm)
C
(mm)
D
(mm)
N
(mm)
W1
(mm)
W2
(mm)
W3
(mm)
W3
(mm)
Material
Tolerance ± 2,0 min. min. min. min. + 2,0 max. min. max.
Value 330,00 1,50 12,80 20,20 100,00 44,40 50,40 43,90 47,40 Polysytrene
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
CLe 001.001 2020-04-07 DIN ISO 2768-1m
DESCRIPTION
WR-CRD SD Card Connector
ORDER CODE
693061010911
SIZE/TYPE BUSINESS UNIT STATUS PAGE
Push & Push - with Card Detection - 9 Pins eiCan Valid 3/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.