Datasheet

Durability 10 000 Mating cycles
Gender Socket
Type Push & Push
Kind Properties:
Insulator Material LCP
Insulator Flammability Rating UL94 V-0
Insulator Color Black
Cover Material Stainless Steel
Contact Material Copper Alloy
Contact Plating Selective Gold
Contact Type Stamped
Material Properties:
Operating Temperature -25 up to +85 °C
General Information:
Properties Test conditions Value Unit Tol.
Rated Current I
R
0.5 A
Working Voltage 100 V (AC)
Withstanding Voltage 1 min 500 V (AC)
Contact Resistance R 100 max.
Insulation Resistance R
ISO
1000 min.
Electrical Properties:
RoHS Approval Compliant [ 2011/65/EU&2015/863 ]
REACh Approval Conform or declared [ (EC)1907/2006 ]
Halogen Free Conform [ IEC 61249-2-21 ]
Certification:
Packaging Tape and Reel & Mylar
Packaging Properties:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
CLe 001.002 2019-01-24 DIN ISO 2768-1m
DESCRIPTION
WR-CRD Micro SD Card Connector
ORDER CODE
693071010811
SIZE/TYPE BUSINESS UNIT STATUS PAGE
Push & Push - with Card Detection - 8 Pins eiCan Valid 2/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.