Data Sheet

Dimensions: [mm]
0,9 ±0,2
1,2 ±0,2
0,5 ±0,3
2,0 ±0,2
Scale - 15:1
Recommended Land Pattern: [mm]
Scale - 15:1
W
WIDE BAND / HIGH SPEED: W = 3,0
HIGH CURRENT: W = 4,0
1,2
1,0
Schematic:
Properties Test conditions Value Unit Tol.
Impedance @ 100 MHz 100 MHz Z 80 Ω ±25%
Maximum Impedance 662 MHz Z 120 Ω typ.
Rated Current ΔT = 40 K I
R
4000 mA max.
DC Resistance R
DC
13 typ.
DC Resistance R
DC
18 max.
Type High Current
Electrical Properties:
Do not use this part constantly beyond the Rated Current, as this will create excessive heat and can
harm the component
Storage Temperature (in original
packaging)
-20 °C up to +60 °C
Operating Temperature -55 °C up to +125 °C
Test conditions of Electrical Properties: +20°C, 33% RH if not specified differently
General Information:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
KaS MHB DIN ISO 2768-1m
DESCRIPTION
WE-MPSB EMI Multilayer Power
Suppression Bead
ORDER CODE
74279220800
SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
0805
001.001 Valid 2017-02-01 eiSos 1/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.

Summary of content (8 pages)