Datasheet

DETAIL OF CHANGE:
Before Change
After Change
Rated current before change said to be at
ΔT=40K.
742843122 I
R
= 500mA
742863122 I
R
= 600mA
742863147 I
R
= 500mA
The rated current before change were
pervious values of ΔT=20K. After change
the rated current values are now for
ΔT=40K definition.
742843122 I
R
= 800mA
742863122 I
R
= 1300mA
742863147 I
R
= 750mA
Label description will be updated to the
new values.
Maximum Impedance at Frequency
742841160 Z
max
= 1300 Ω @ 550 MHz
742841210 Z
max
= 1700 Ω @ 550 MHz
742863122 Z
max
= 550 Ω @ 700 MHz
742861118 Z
max
= 270 Ω @ 500 MHz
742861160 Z
max
= 1000 Ω @ 450 MHz
742861210 Z
max
= 2200 Ω @ 550 MHz
742862160 Z
max
= 1700 Ω @ 700 MHz
742863122 Z
max
= 500 Ω @ 600 MHz
742863147 Z
max
= 1000 Ω @ 600 MHz
742863160 Z
max
= 1250 Ω @ 500 MHz
Maximum Impedance at Frequency
amendment according to the typical curves
produced from a newly released
measurement method.
742841160 Z
max
= 1800 Ω @ 650 MHz
742841210 Z
max
= 1750 Ω @ 500 MHz
742863122 Z
max
= 400 Ω @ 750 MHz
742861118 Z
max
= 300 Ω @ 450 MHz
742861160 Z
max
= 900 Ω @ 350 MHz
742861210 Z
max
= 2200 Ω @ 450 MHz
742862160 Z
max
= 1500 Ω @ 700 MHz
742863122 Z
max
= 350 Ω @ 640 MHz
742863147 Z
max
= 780 Ω @ 600 MHz
742863160 Z
max
= 950 Ω @ 600 MHz
No change in label.