Data Sheet

Dimensions: [mm]
0,3 ± 0,1
1,65 ± 0,2
0,9 ± 0,2
0,5 ref.
1,15 ± 0,2
Scale - 20:1
Recommended Land Pattern: [mm]
0,625
0,762
0,65
Scale - 20:1
Schematic:
Properties Test conditions Value Unit Tol.
Inductance 250 MHz L 18 nH ±5%
Q-Factor 250 MHz Q
min.
35 min.
DC Resistance @ 20 °C 0.12 Ω max.
Rated Current ΔT = 15 K I
R
700 mA max.
Self Resonant Frequency f
res
3100 MHz min.
Electrical Properties:
It is recommended that the temperature of the component does not exceed +125°C under worst
case conditions
Ambient Temperature (refering to
I
R
)
-40 °C up to +110 °C
Operating Temperature -40 °C up to +125 °C
Storage Temperature (in original
packaging)
-10 °C up to +40 °C
Test conditions of Electrical Properties: +20°C, 33% RH if not specified differently
General Information:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
KaS JoMa DIN ISO 2768-1m
DESCRIPTION
WE-KI SMD Wire Wound Ceramic
Inductor
ORDER CODE
744761118C
SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
0603C
005.000 Valid 2017-02-13 eiSos 1/5
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.