Datasheet
Bezeichnung :
description :
M
A 25,0 max. mm
B 17,0 max. mm
C 7,5 ± 0,5 mm
D 10,7 ± 0,5 mm
E 26,5 max. mm
F 3,0 ± 0,5 mm
G 0,7 ref. mm
@@FRM 1@@
Eigenschaften /
p
ro
p
ertie
s
Wert / value Einheit / unit tol.
Leerlauf-Induktivität
inductanc
e
DC-Widerstand
/
DC-resistanc
e
Nennstrom
/
nominal curren
t
Nenns
p
annun
g/
nominal voltag
e
33%
+25°C
1500 V,50 Hz
5mA , 2 sec.
Sockel / base:
Draht / wire:
Verguß / molding:
MST Version 6 06-06-16
MST Version 5 05-11-18
MST Version 4 04-10-11
MST Version 3 04-06-22
MST Version 2 03-12-01
MST Version 1 03-07-03
Name Änderung / modification Datum / date
Würth Elektronik
........................................................................
F Werkstoffe & Zulassungen / material & approvals
G Eigenschaften / general specifications:
UL94V-0
Klimabeständigkeit/ climatic class: 40/125/21UL94V-0
2UEWF (155°C)
Freigabe erteilt / general release:
Kunde / customer
C Schaltbild / schematic: B Elektrische Eigenschaften / electrical properties:
UL94V-2
Abstandhalter / spacer:
mH
max.
L
O
1,0
http://www.we-online.com
Datum / date
.........................................................................
.
Unterschrift / signature
Kontrolliert / approved
Würth Elektronik eiSos GmbH & Co. KG
D-74638 Waldenburg · Max-Eyth-Strasse 1 -3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400
Geprüft / checked
.........................................................................
.
........................................................................
Spezifikation für Freigabe / specification for release
DATUM / DATE : 2006-06-16
max.
V
AC
Testbedingungen / tes
t
condition
s
250
mΩ
6,0
±30%
Kunde / customer :
STROMKOMP. DROSSEL WE-CMB
COMMON MODE CHOKE WE-CMB
Artikelnummer / part number :
744823601
R
DC
13
A Mechanische Abmessungen / dimensions:
10 kHz / 500µA
@ 25°C
A
I
DC
WAYNE KERR WK3260B/WK3265 für/for L
0
/L
N
und/and RDC
U
N
E Testbedingungen / test conditions:
typ.
D Prüfgeräte / test equipment:
Luftfeuchtigkeit / humidity:
Umgebungstemperatur / temperature:
Prüfspannung / testing voltage
HP 34401 A für/for I
N
Betriebstemp. / operating temperature: -40°C - + 125°C
Übertemperatur / temperature rise: < 55 K
It is recommended that the temperature of the part does
not exceed 125°C under worst case operating conditions.
1
2
N1
3
4
N2
A
E
G
B
F
C
D
12
3
4
LF
This electronic component has been designed and developed for usage in general electronic equipment. Before incorporating this component into any equipment where higher safety and
reliability is especially required or if there is the possibility of direct damage or injury to human body, for example in the range of aerospace, aviation, nuclear control, submarine, transportation,
(automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc, Würth Elektronik eiSos GmbH must be informed before the
design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and
reliability functions or performance.
SEITE 1 VON 1