Data Sheet

1.1
1.0
REV
2014-08-14
2014-05-14
DATE
SSt
SSt
BY
PSL
PSL
CHECKED
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
DESCRIPTION
WCAP-FTX2 Foil Capacitors
Order.- No.
890324024002CS
SIZE
A4
Size: Pitch 12.5 mm - PL 4
A Dimensions: [mm]
P ±0.5
L ±0.5
H ±0.5
W ±0.5
PL min.
Pin Ø ±0.05
d1
12.5
15.0
12.5
7.0
4.0
0.6
0.9
B Recommended hole pattern: [mm]
C Schematic:
D1 Electrical Properties:
Properties
Capacitance
Rated voltage
Isolation Resistance
Dissipation factor
Dissipation factor
Dissipation factor
Rate of Voltage Rise
Dielectric strength Pin to Pin
Dielectric strength Pin to Case
Test conditions
1 V/ 1 kHz ± 0.2 kHz
1 min @ 100V (DC)
@ 1 kHz
@ 10 kHz
@ 100 kHz
1 minute
1 minute
C
U
R
R
Iso
DF
DF
DF
dV/ dt
Value
0.2200
275
> 30000
< 0.10
< 0.20
< 2.0
240
1333
2000
Unit
µF
V (AC)
%
%
%
V/ µs
V (DC)
V (AC)
Tol.
± 10%
min.
max.
max.
max.
max.
E General information:
X2-Safety Class Capacitor
Storage Conditions: 35°C, <45% RH
Operating Temperature: -40°C to +105°C
Climate category: 40/ 105/ 56/ B
Maximum Selfheating (rated): 7°C
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
FIT according to separate documentation
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.

Summary of content (8 pages)