Specifications

test (silk
screen)
40±2℃的恒温水浴箱中,试验时间 48
时;
Test conditions: a), the test solution is: pure water
400ml, sodium chloride 8g, 1 ml of ammonium
chloride, 1 mL of acetic acid, 6 ml of lactic acid,
less sodium hydroxide, pH = 4.7; b), soak
solution The filter paper is attached to the surface
of the sample and the back, and the product is
sealed in the filter paper, and then placed in a
constant temperature water bath of 40 ± 2 ° C, the
test time is 48 hours;
not allowed to be dyed, and the outer
surface does not allow corrosion and
delamination. (Refer to our remote
control quality specification
requirements)
4.2.8
百格测试
(表面喷漆)
Baige test
(Surface
painting)
用百格刀,间隔 1 ㎜左右,横竖各划 11 条,
形成 100 个小方格。使用毛刷或将划线处的喷
涂粉屑消除干净。用 3M600 带完全粘合百
格区,将胶带呈 45°角 1 秒内撕起。粘揭 3
次,每次使用新胶带。
With a hundredger knife, the interval is about 1
, and there are 11 strokes to form 100 small
squares. Use a brush or eliminate the discharging
of the scribe. With a 3m600 tape, Bonded
Brightness, torn it in a 45 ° angle of 45 ° in 1
second. Paste 3 times, using a new tape each
time.
线沿
5 %(当测试面积不够 100 个小
(参照我司遥控器质量规范要求)
Baige test scriberal edge is flat, the
shedding area is 5% (when the test
area is not 100 small square, the
shedding area is determined by the
equivalent proportion) (refer to our
remote control quality specification
requirements)
4.2.9
按键操作力
Button operation
用一个直径 4mm 的测试头在按键中心
直下压测试其操作力
Test its operating force with a
test head of 4mm in diameter.
所有按键:1.5±0.3N
All buttons: 1.5 ± 0.3n
4.2.10
按键回弹
Press button
rebound
按压任意按键的任意位置
Press any position of any button
按键不可以卡在上盖上
Button can not be card on
the cover
4.2.11
按键寿命
Button life
装有普通电池遥控器放在按键寿命机器上,使
用顺序模式,分别测试 OK 键和任意一个其他
按键,测试后,遥控器应还能正常发码;遥控
器按键手感正常,无异常。(参照等级标准)
With ordinary battery remote
control, on the button life
machine, use the order mode, test
the OK key and any other button,
after testing, the remote control
should also issue normally; the
remote control button is normal,
no abnormality. (Reference grade
standard)
不可有机械,电气,功能的失
Do not have mechanical,
electrical and functional
failure
4.2.12
电池盖开合寿命
Battery cover
opening life
连续开合电池 100
Continuously open the battery
cover 100 times
电池开合力不可有大的改变,
无异常
Battery is not changed, no
abnormalities
4.2.13
电池盖开合
Battery cover
电池盖正常用力能打开扣
The battery cover is normal to
open the buckle
应能顺利打开而不借助任何工
It should be open to open
without any tools.