Quick Start (for DMX control)
1. Connect the Equipment
a. Connect the Cygnus to a mounting pipe with a C-clamp.
b. Connect the safety cable to the mounting pipe.
c. Connect the Cygnus to a DMX source with a 5-pin cable
d. Connect to AC power (100 – 240 VAC 50/60Hz)
2. Set DMX Address to 1
a. Press ‘Menu’ until the display reads ‘Adr’. If ‘GrP’ is displayed for 1
second then the unit is in grip mode. To exit grip mode, press and hold
the leftmost two buttons until ‘nor’ is displayed. Then repeat this step.
b. Press ‘Enter’
c. Press the ‘+’ or ‘-’ keys to select ‘001’
d. Press ‘Enter’ to save setting
3. Set Video Mode to Off
a. Press ‘Menu’ until the display reads ‘HSP’
b. Press ‘Enter’
c. Press the ‘+’ or ‘-’ keys to select ‘OFF’
d. Press ‘Enter’ to save setting
4. Set Fan Speed to low
a. Press ‘Menu’ until the display reads ‘FAn’
b. Press ‘Enter’
c. Press the ‘+’ or ‘-’ keys to select ‘Lo’
d. Press ‘Enter’ to save setting
5. Set The Color Temperature
a. Press ‘Menu’ until the display reads ‘CoL’
b. Press ‘Enter’
c. Press the ‘+’ or ‘-’ keys to select 28-60 for color temps from 2800 to
6000K. The option “InP” allows the color temp to be controlled from
DMX input on the 2nd channel.
d. Press ‘Enter’ to save setting