Specifications

28
SEr Err! The RDM unique ID has been corrupted. The unit will operate
normally but should not be used in an RDM environment. Contact
the factory for assistance.
DMX Channel Assignments
! Channel 1 controls Intensity (0 - 100%).
Channel 2 optionally controls Color Temperature (0-100% for 2800 - 6000K).
See Appendix A for values.
RDM Functionality
Cygnus is compliant with the RDM v1.0 standard and can be used with the
Wybron InfoTrace system or other RDM systems. By definition, all required
RDM parameters are supported including discovery, device info, DMX start
address, identify device, etc.
Additional RDM functions supported include:
Status and Queued messages. This allows the device to let the controller know it
has something to say—like ‘my address has been changed locally’
Device Model Description: gives the controller a human readable description of
the Cygnus
Manufacturer Label
Device Label: user definable field up to 32 characters allowing the user to give
it a meaningful name in the particular application like ‘Star curtain 2’ or ‘Shark
display upper right’.
Software version information
DMX personality: The Cygnus personalities include selection of Fan Speed
mode, color temp internal/DMX, and Video (High Speed) Mode on/off.
DMX Start Address: This can be set remotely through an RDM system.
Slot description: explanation of the function of each of the Cygnus’s DMX
channels.
Sensor information includes LED board temperature and white color
temperature.
Device operational hours.