Instruction manual

22
Technical Support: support@wyrestorm.com US: +1 866 677 0053 EU: +44 (0) 1793 230 343
1
2
3
4
This setting is locked by default.
UTP LONG CABLE MODE – As with HDMI Long
Cable Mode, if signal transmission quality is affected by a
Cat5e/6/7 cable run reaching the maximum distance
capacity (70m / 230ft using RX-1UTP-IR-70), switching
Long Cable Mode to ON will instruct the matrix to attempt
to improve transmission over the UTP in an effort to
improve signal quality.
This mode should NOT be used as a general means to
lengthen transmission distance – we recommend installers
be aware of product specifications and use equipment
best suiting the requirements of the project. This setting
is locked by default.
Lock/Unlock – To gain access to Long Cable Mode
settings, press ‘unlock’ and enter
‘877379’
NOTE This password cannot be changed
UTP ENFORCE – used to encourage EDID/HDCP
communication between INPUT and OUTPUT devices.
Switching output settings to ON instructs the matrix
to output a signal regardless of device EDID/HDCP or
hotplug data – such information is circumvented to force
communication in the event of problems between sync
devices. Default setting is OFF.
If difficulties are encountered receiving a signal from a
particular source to a display, change UTP ENFORCE
setting to ON for that particular OUTPUT.
Although this setting can be used to fix EDID
communication problems, we recommend this setting
for system debugging by the installer only, and not for
operation by the end user.
EDID COPY SETTING – Copies EDID information
directly from one device to another to aid transmission
if communication problems arise between incompatible
devices. Use the dropdown boxes to select which INPUT/
OUTPUT devices to copy from and where to be copied to.
FACTORY RESET – restores all matrix settings to
factory default. This action cannot not be reversed.
Set IP The matrix can also be controlled over LAN.
Selecting the Set IP button in the main COMCTL
screen allows access to IP functions that obtains and
stores IP address information necessary for LAN control.
Clicking opens a pop-up window in which you can
choose to let the system automatically detect your IP
address, with the result displayed in the box below.
Alternatively, if the system cannot detect an IP address,
select ‘Use the following IP Address’ and you can add
manually.
Selection enables the IP address to be obtained
automatically, with the result appearing in the white box
below.
Should no address appear or if the system is unable
to detect an IP address, select option to manually
input the IP address.
Click
to complete the process or
to exit and return to the main screen.
NOTE To access matrix control over LAN, enter the
IP address of the matrix into your internet browser
and you will be directed to the web control screen.
IR SET - The MX-PP-POH range supports third party
control systems and learning handsets. Pressing the IR
SET button in the COM CTL main screen allows access
for users to enter new IR code or modify existing code
and assign it to inputs and outputs so control using third
party systems is possible.
To input or amend IR code, follow the steps below:
1- Press
to instruct COM CTL to read the IR code from the control
system. The resulting data will appear in the central
section.
2- Use your cursor to click into the box containing the IR
data you wish to change.
4
14
14
5
6
7
8
15
1
2
3
4
COM CTL