Instruction manual

12
Technical Support: support@wyrestorm.com US: +1 866 677 0053 EU: +44 (0) 1793 230 343
54321
9
Ground
RXD TXD
876
Fe
male connector - 9 holes
12345
6
Ground
RXDTXD
789
Male connector - 9 holes
RXD Receive serial data from PC
TXD Transmit serial data to PC
Baud rate 9600bps
Data bits 8bits
Parity None
Stop bits 1
Flow control None
Com Port Setting
1
2
3
4
1
2
3
4 5
6
7 8
9
ADVANCED OPERATION
i. RS232 Control
Should third party control be required, please see below
for control system configuration and hex code input. The
RS232 connection on the matrix is female DB9 Users
can use a USB to RS232 cable or a direct male to female
serial cable.
ii. COM CTL
After fully connecting all inputs and outputs to the matrix
and installing the software, on opening the program
the control window will display information from the
matrix, such as messages received from the switch such
as input/output details, firmware version and control
commands/HEX codes that allow the system to be
controlled remotely, as well as buttons used to navigate
the screen.
Receive Message Window – displays messages
received from the matrix, such as input/output settings
and command selections.You can view the current
condition of all input/output ports by pressing the
button.
Pressing
will delete the previous message received in the window.
Send Message Window – Input your serial
commands for the matrix in the Send Message Window
- such as instructions for outputs or to enter update mode
– and click the Send button to deliver the message to the
Matrix.
NOTE To see the firmware version currently used in
the system – power off and repower while the matrix is
connected to COM CTL. The firmware version and
creation date will be displayed together with the normal
output state of the matrix.
Set IP Button – allows you to set the IP address to
be used by the system.
Clicking opens a pop-up window in which you can
choose to let the system automatically detect your IP
address, with the result displayed in the box below.
Alternatively, if the system cannot detect an IP address,
select ‘Use the following IP Address’ and you can add
manually.
Click
to complete the process or
to exit and return to the main screen
UTP Set – Default setting is OFF for normal Matrix
operation to obey device EDID/HDCP commands and
high hotplug settings when outputting a signal.
Switching output settings to ON instructs the matrix
to output a signal regardless of device EDID/HDCP
or hotplug data – such information is circumvented to
encourage communication in the event of problems
between sync devices.
We recommend this setting for system debugging by
the installer and not for operation by the end user.
Female connector - 9 holes
Male connector - 9 pins