User Manual
HDMI Wiring
IMPORTANT! Wiring Guidelines
• The use of patch panels, wall plates, cable extenders, kinks in cables,
and electrical or environmental interference can have an adverse effect
on HDMI transmission limiting performance. Steps should be taken to
minimize these factors (or remove completely) during installation for
best results.
• WyreStorm recommends using HDMI cables from a high quality brand
such as WyreStorm Express.
• Active HDMI cables or extenders must be used for distances greater
than 10m between the splitter and connected devices in order to
maintain the highest level of video performance.
RS-232 Wiring
RS-232 Connection Guidelines
The following wiring diagram shows the pinouts for the extender set.
While not shown, connect the TX (transmit) to RX (receive) pins at the
control system or PC side of the cable.
Most control systems and computers are DTE where pin 2 is RX, this can
vary from device to device. Refer to the documentation for the connected
device for pin functionally to ensure that the correct connections can be
made.
Pin 1:
Pin 2:
Positive (+)
Negative (-)
Pin 3: Ground (GND)
Wire colors shown are for pin identificaiton only and do not
represent any wiring standard.
1 2 3
EDID Settings
EDIDs can be congured to resolve issues with video output on displays
that may not accept the maximum resolution available from the source.
Note:
• Ensure that a display is connected and powered On to the selected
output before copying EDIDs or the copy will fail. When this occurs,
EDID will be set to 4K@30Hz 2ch.
• Power to the splitter must be cycled (Off/On) after changing dip
switches in order for the setting to take effect.
Position Video Resolution and Audio
0 Copy EDID from HDMI output1 (default setting)
1 1080i 2ch
2 1080i Dolby/DTS 5.1ch
3 1080i, HD Audio
4 1080p 2ch
5 1080p Dolby/DTS 5.1ch
6 1080p HD Audio
7 3D 2ch
8 3D Dolby/DTS 5.1ch
9 3D HD Audio
A 1280x1024 DVI
B 1920x1080 DVI
C 1920x1200 DVI
D 4K@30HZ 2ch
E 4K@60HZ 2ch
F Copy EDID from HDMI output2
Copyright © 2015 WyreStorm Technologies | wyrestorm.com