User Manual

neutral, please connect it to the black wire on the inverter. It CANNOT
connect the red and yellow or black and yellow line to power the load.
Do not expose the inverter to temperatures exceeding 104
(40
).
CAUTION! SAFETY INSTRUCTIONS - INVERTER RELATED
Preventing Reverse Polarity on the DC Input Side
When making battery connections on the input side, make sure that the
polarity of battery connections is correct (Connect the Positive of the battery to
the Positive terminal of the unit and the Negative of the battery to the Negative
terminal of the unit). If the input is connected in reverse polarity, DC fuse(s)
inside the inverter will blow and may also cause permanent damage to the
inverter.
NOTE: Damage caused by reverse polarity is not covered by warranty!
Preventing connection of the inverter AC side together. Unstackable.
No stack use of several off grid inverters. Connecting the inverter AC side
together will cause the failure of the inverter immediately. No AC output
connection in series or in parallel. The AC output of the inverter can not be
synchronized with another AC source. No connection to any electrical breaker
panel/load center which is also from utility power or generator. The AC power
back to the inverter will instantly damage the output section of the inverter, may
also cause a fire or safety hazard.
Connection from Batteries to the DC Input Side Sizing of Cables
and Fuses
The cable for connecting the battery and the inverter will affect the inverter
output performance, please use all of the cables supplied in the pack or larger
cable. The fuse between the battery and the inverter will also affect the output
power. Please calculate the fuse or breaker amper with this formula inverter
power/input voltage * 2.
Do not overload. Do not use for the equipments with exceeding power
capacity than the power inverter’s rated power. Better to use 80% of the
rated power of the power inverter for longevity of the power inverter. Pay
attention to the inductive load with 5-10 times higher.
Product Introduction
This inverter transforms the DC power from the battery to standard household
AC power for AC appliances. It adopts highly advanced intelligent control chips
with software and well designed hardware. The inverters’ output wave form is
real pure sine wave, which is a good as the grid power. The pure sine wave
inverter has high efficiency and stable performance. It has sound protections
including overload protection,over current protection, short circuit protection,