2. Input DC voltage display.
3. Output AC voltage display.
4. Socket type for AC output
5. Wire terminal for AC output: red line for live, black line for neutral, yellow
line for ground.
NOTE:
1. NO connect the red wire with the yellow one or the black one with yellow
one, the voltage from this connection is not the true voltage, it will damage
your equipment.
2. If the house neutral wire is combined with the ground, connect the black
wire with it, Do not connect the inverter yellow wire with the black wire
together.
3. The terminal cover panel is on the fuse bag, put it on when it is in use.
4.5 Operation Instruction
1. Red binding post for positive, black binding post for the negative.
2. Use the cable we sent to connect the battery and inverter, otherwise, the full
output power is not guaranteed.
3. It is recommended the inverter connect after the battery directly. Do not
connect it to the solar controller.
4. For 24/7/365 long time usage, it is recommended 70% of the rated power
usage.
5. The battery voltage must be the same as the inverter input voltage.
4.6 AC Side Connection
Make sure the inverter power switch is in the OFF position.
Connect the inverter to a fully charged battery or battery bank.
Connect the electric appliance to AC output socket of the inverter.
Turn the inverter “ON” the blue LED should light up, indicating power is on
and inverter is functional. Turn on the Appliance.
When finished, turn off the appliance firstly, then turn inverter power switch to
“OFF” position, this will shut down the inverter.