Pure Sine Wave Inverter Product Manual CE EMC RoHS FCC YUEQING RELIABLE ELECTRIC CO.,LTD.
Read this guide before installing or using the inverter and save it for future reference. Safety First Incorrect installation or misuse of the inverter may result in danger to the user or hazardous conditions. We urge you to pay special attention to all CAUTION and WARNING statements. CAUTION statements identify conditions or practices that may result in damage to other equipment. WARNING statements identify conditions that may result in personal injury or loss of life.
neutral, please connect it to the black wire on the inverter. It CANNOT connect the red and yellow or black and yellow line to power the load. Do not expose the inverter to temperatures exceeding 104℉ (40 ℃).
battery reverse connection protection, high temperature protection, high or low battery input protection, built-in fuse protection. 1. Inverter Specification 1.1 Rated Continuous power: 300W/500W/600W/800W/1200W/1300W/1500W/2000W/ 2500W/3000W/3200W/3500W/4000W/5000W/6000W/7000W/8000W/10000 W/12000W/15000W 1.2 Surge output power: 2 times higher than the rated power 1.3 Standby input power: 300w ~ 800w <10W, 1000w~2000w <15W, 2500~3000W<30W , 3500~4000W <35W, 5000W~8000W<40W 1.
2.1 Normal working indication: both DC and AC display lit, blue light lit, red light flashing or no lit. 2.2 Abnormal input voltage indication: Input low voltage alarm red light lit, alarm on Input low voltage protection Red light lit, alarm on, no AC output Input high voltage protection Red light lit, no AC output 2.3 Abnormal output indication: Output overload or short circuit Red light lit, no AC output protection.
4.3.3. Recommended Size of battery cables and fuses. Spec. Of Inverter Spec. Quantity Note 2 300W 4mm /AWG11 2 1 red 1 Blue or black 2 500W-1000W 10mm /AWG7 2 1 red 1 Blue or black 2 1500W-2500W 10mm /AWG7 4 2 Red T2 Blue or black 2 1500W-2500W 20mm /AWG4 2 1 Red 1 Blue or black 2 Alluminum shell (2 of 10 mm combined into one) 3000W 10mm2/AWG7 4 2Red 2Blue or black 4000w 16mm2/AWG5 4 2Red 2Blue or black 2 5000W 16mm /AWG5 6 3Red 3Blue or black 2 6000w-10000W 16mm /AWG5 8 4Red 4Blue or black Length:50cm/ 19.
2. Input DC voltage display. 3. Output AC voltage display. 4. Socket type for AC output 5. Wire terminal for AC output: red line for live, black line for neutral, yellow line for ground. NOTE: 1. NO connect the red wire with the yellow one or the black one with yellow one, the voltage from this connection is not the true voltage, it will damage your equipment. 2.
Note: When using wired remote controller make sure the inverter “ON/OFF” Switch is in the “ON”position. IMPORTANT: Vehicle batteries are designed to provide brief periods of very high current needed for engine starting. They are not intended for constant deep discharge. Regularly operating the inverter shortens the life of the battery. Consider connecting the inverter to a separate deep discharge type battery if you will be frequently running electrical products for extended periods of time. 4.
supplied to a transformer, the transformer draws very heavy surge of “Magnetization Inrush Current” for a few millisecs that can reach up to 10 times the Maximum Continuous Rating of the Transformer. Devices like Infrared Quartz Halogen Heaters (also used in Laser Printers) / Quartz Halogen Lights / Incandescent Light Bulbs using Tungsten heating elements: Tungsten has a very high Positive Temperature Coefficient of Resistance i.e. it has lower resistance when cold and higher resistance when hot.
5 Trouble Shooting: WARNING! Do not open or disassemble the inverter without the manufacturer permission. Attempting to service the unit Possible Cause Solutions yourself may cause the risk of electrical shock or fire. Problems and Symptoms Can not turn on Battery damaged, or bad DC Change battery, check DC cable connection cables and terminations No AC power output. Red Output overload or short Decrease load, check AC LED always on circuit cable. Remove load, check output No AC power output.
It depends on the power of the appliances. Choose the power inverter based on the maximum power of the AC load. For resistive load such as cooker for 800w, choose1000W inverter. For inductive load such as refrigerator, A/C,pump,motor, compressor ect, the surge power can be 5-10 times higher. Please choose the power inverter with the power of 5-10 times or higher. 6.3. How long can the power inverter last to power up my appliances? It depends the power of the AC appliances and the capacity of the batteries.
6.4.3Series Parallel Connection The following chart shows a series- parallel connection consisting of four 6V, 200AH batteries to get a 12V, 400Ah battery bank. For string 1, two 6v, 200ah batteries are connected in series to get a 12v, 200Ah battery. Do the same to have string 2. The 2 strings are connected in parallel to have 12v,400Ah bank. 7.