Installation Sheet

Installation Procedure:
1. Rough opening size requirements
SLIM-BR 9.0” 4.5”
SEB-BR 8.5” 7.6”
MDEB-BR 8.5” 7.6”
DVEB-BR 8.5” 12.6”
DHEB-BR 12.6” 8.5”
TVEB-BR 8.5” 12.6”
THEB-BR 12.6” 8.5”
Operation and Maintenance Procedures
Our products are designed to require minimum or no
maintenance. The recessed cavity boxes and in-line sleeves
contain only one or two moving parts (gravity dampers)
depending on the model.
Annual Inspections and Maintenance:
An annual visual inspection of the dryer, bathroom and
residential kitchen exhaust termination box or sleeve is
recommended.
Dryer Applications:
Inspection of exhaust boxes or in-line sleeves used in
conjunction with dryer exhaust may require more frequent
inspection due to frequency of use.
Required:
Removal of all visible lint in and around the box or sleeve,
particularly around the damper frame assembly and gravity
damper.
Recommended:
Conrmthattheductbetweenthedryerandthetermination
box is free of lint build up.
OPERATION AND MAINTENANCE PROCEDURES
INSTALLATION
X Vent Box
8022 Providence Rd. Suite: 500-145
Charlotte, NC 28277
customerservice@xventbox.com.
Installation Procedure:
1. Apply a continuous bead of
construction sealant around
the backside of the perimeter
mounting flange.
(Recommended Sealant:
Sikaflex- 201 or other high grade
exterior sealant. Sealant not included)
2. Moisten rubber seal with water and
insert sleeve into duct. Note: Metal duct
should be true round and free of defects
to insure a proper seal.
3. Mechanically fasten front louver frame to exterior wall
surface with 3/16” X 2 ¼” flat head stainless steel screws:
Four (4) for 4ILS-8F and 6ILS-8F models Six (6) for 4ILS-12v,
4ILS-12H, 6ILS-12V, 6ILS-12H, 4/4ILS-12V, 4/4ILS-12H,
4/6ILS-12V and 4/6ILS-12H models
(Screws not included)
4. Attach front louver to front louver frame with the
stainless steel screws provided.
MODELS: 4ILS-8F | 6ILS-8F | 4ILS-12V | 4ILS-12H | 6ILS-12V | 6ILS-12H
4/4ILS-12V | 4/4ILS-12H | 4/6ILS-12V | 4/6ILS-12H
2. Apply a continuous bead of construction sealant around
the backside of the perimeter mounting flange.
(Recommended Sealant: Sikaflex- 201 or other high grade
exterior sealant. Sealant not included)
3. Insert exhaust box into exterior rough opening, level
horizontally and vertically.
4. Mechanically fasten with non-corrosive 3/16” X 2” screws:
Four (4) for SLIM-BR, SEB-BR and MDEB-BR models
Six (6) for DVEB-BR, DHEB-BR, TVEB-BR and
THEB-BR models (Screws not included)
5. Insert properly sized metal duct(s) into rear duct port
assembly and secure with metal duct tape.
(Duct tape not included)
MODELS: SLIM-BR | SEB-BR | MDEB-BR | DVEB-BR | DHEB-BR
TVEB-BR | THEB-BR
4
2
3
5
2. Apply a continuous bead of construction sealant around
the backside of the perimeter mounting flange.
(Recommended Sealant: Sikaflex- 201 or other high grade
exterior sealant. Sealant not included)
3. Insert exhaust box into exterior rough opening, level
horizontally and vertically.
4. Mechanically fasten with non-corrosive 3/16” X 2” screws:
Four (4) for the SLIM-S, SEB-S and MDEB-S models
Six (6) for the DVEB-S, DHEB-S, TVEB-S and THEB-S models
(Screws not included)
5. Insert properly sized metal duct(s) into rear duct port
assembly and secure with metal duct tape.
(Duct tape not included)
MODELS: SLIM-S | SEB-S | MDEB-S | DVEB-S | DHEB-S | TVEB-S | THEB-S
4
2
5
3
BR | SERIES
S | SERIES
ILS | SERIES
Installation Procedure:
1. Rough opening size requirements
SLIM-S 9.0” 4.5”
SEB-S 8.5” 7.6”
SEBRND-S 8.5” 7.7”
MDEB-S 8.5” 7.6”
DVEB-S 8.5” 12.6”
DHEB-S 12.6” 8.5”
TVEB-S 8.5” 12.6”
THEB-S 12.6” 8.5”
A
B
(A) LENGTH (B) WIDTH
A
B
(A) LENGTH (B) WIDTH